Serial Interface RS4228.3.4 Reading the Software Version, VERSIONName:Description:VERSIONThe sensor transmitts the software version.Format Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9“+” “+” “+” 0x0D „I“ „L“ 0x09 0x00 noneReply Byte 1 Byte 2 Byte 3 Byte 4 Byte 5„I“ „L“ 0x89 Quantity Info stringCommand error-freeByte 1 Byte 2 Byte 3 Byte 4“I“ “L“ 0x89 0x07Version is a readable ASCII string: 1.001Default setting:Median offFaulty command Byte 1 Byte 2 Byte 3 Byte 4 Byte 5“I“ “L“ 0xC9 0x01 Error code8.3.5 Average On/Off, MEDIANName:MEDIANDescription: Switches between „Averaging on“ and „Averaging off“. The median is generated from a presetnumber of measurement values. Here the inputted measurement values (3 measurement values) are resortedafter each measurement. The average value is then outputted as the median. When the median is generatedin the controller only 3 measurement values are taken into account, i.e. a 0 median is not possible. Thismeans that individual interference pulses can be suppressed. The measurement value curve is not smoothedto a great extent.Byte 9 = 0; Median offByte 9 = 1; Median on<strong>optoNCDT</strong> <strong>1402</strong>Page 46