Campbell Section 5 - <strong>Works</strong> <strong>Approval</strong> Project Ref: 110029Prepared for <strong>the</strong> Land Development Agencydepth of cover over this service is believed to conflict with <strong>the</strong> proposed intersection upgrades atConstitution Avenue / Wendouree Drive / Road 3. It is anticipated that a diversion of <strong>the</strong> water mainwill be necessary at this location; however, this will be verified during <strong>the</strong> detailed design.ProposalThe existing 300mm water main on Constitution Avenue may need to be lowered to achieve cover ofat least <strong>the</strong> minimum 750mm under <strong>the</strong> proposed intersection at Constitution Avenue / WendoureeDrive / Road 3.It is proposed that 150mm diameter water mains be looped around <strong>the</strong> blocks throughout <strong>the</strong>development. This new water network will be supplied from <strong>the</strong> existing 300mm water main inConstitution Avenue and <strong>the</strong> 150mm water mains in Anzac Park East and Page Street. ActewAGLwere consulted and advised Cardno that <strong>the</strong>y have no issues with <strong>the</strong> water master plan proposals.Water ties to each Block will be 150mm diameter plastic pipe.ACT Fire and Rescue has also been consulted over <strong>the</strong> water master plan for Campbell Section 5and <strong>the</strong> site has been classified as Fire Risk Category F4. This classification requires hydrants to bespaced at 60m intervals and capable of delivering 60L/s at all times.8.12.4 ElectricityExistingUnderground electricity infrastructure is located in <strong>the</strong> verges of Constitution Avenue, CreswellStreet and Chowne Street. The high voltage electric network is located along <strong>the</strong> western verge ofCreswell Street. ActewAGL is undertaking an electrical master plan to service <strong>the</strong> site.It is anticipated that electrical services will require relocation on Creswell Street and ConstitutionAvenue; however, this will be verified during <strong>the</strong> detailed design.ProposalIt is proposed that street lighting and electrical infrastructure will be provided throughout <strong>the</strong>Campbell Section 5 development.Discussions with ActewAGL have identified a possible High Voltage supply to <strong>the</strong> site from atransformer on Getting Crescent. This feed would <strong>the</strong>n supply sub-stations within <strong>the</strong> site.It is proposed that substations be located within recesses in <strong>the</strong> development Blocks.A dedicated trench for High and Low voltage electricity will be provided through <strong>the</strong> development asrequested by ActewAGL to service <strong>the</strong> substations easements within each block.November 2012 Cardno 79

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!