Sheet DP026BREAKDOWN DETECTION FLOW CHARTNO COMPENSATION MOVEMENT(UP AND / OR DOWN)Folio 4/5CMaintain the controlactivated and check for12V voltage at terminals401 (up) and 402 (down) ofthe printed circuit12VOKNOOpen the platform controlpanel and check the wiring ofthe compensation switch SA5YESReplace the U1 moduleSee FicheC058WiringOKNORepair wiringYESCheck the electric continuity ofthe switch contacts when closedENDNOThe faultpersistsENDYESReplace theprinted circuitSee FicheC063ContinuityOKNOENDYESReplace thecompensation switchSA5See FicheC043Repair the connection or replace the wiringharness between the compensation switchSA5 and the printed circuit of the turntablecontrol panelENDEND