135 Repair manual5.18 - OTHER FUNCTIONS: OVERLOAD, SAFETY…5.18.1 -OverloadThe overload through SQ6 cuts all the ordered movements of the platform. Whenone passes in turntable position, one recovers the movements with a limitedspeed. Moreover the turntable buzzer sounds.5.18.2 -Fuse safetyIf an electrovalve is controlled permanently for any reason (short-circuitedelectrovalve, etc ...) fuse FU7 is destroyed.The emergency stop is relayed. For any reasons, we must constantly monotorthat the relay does not remain stuck after an emergency stop.5.18.3 -Fail-safeIf the fail-safe is held for 10 seconds (Controller or neutral), movement is devalidated..x = 6s for travelx = 4s for movements5.18.4 -Indicator defectIf SQ6=0 or (SA8a=1 or SA8b=1 or (HM2=1 and SM2ab=1))or (SA13a=1 or SA13b=1 or (HM31=1 and SM1ab=1)))then HL9=136