Sheet DP016BREAKDOWN DETECTION FLOW CHARTTHE MOTOR DOES NOT START,THE STARTER IS NOT ACTIVATEDFolio 2/3AOpen the turntable control panel andcheck the state of fuses FU1, FU4and FU8Fuses OKNOYESCheck the 12V on line 242 of theturntable control panelReplace the defective fuseEND12VOKNOYESActivate switch SB3 (turntable)or SB4 (platform) and checkcontinuity between the 2 switchterminalsRepair key switch SA1 wiringor replace the switchENDContinuityOKNOBYESReplace the defectiveswitchSee FicheC044END