Sheet DP023BREAKDOWN DETECTION FLOW CHARTaNO MOVEMENT AVAILABLE(FROM TURNTABLE OR PLATFORM CONTROL PANELS)Folio 2/5AMovementOKNOYESC- Open the turntable control panel- Press the pedal and activate the boomlifting manipulator SM31.- Check that the LED associated withelectrovalve YV1 is on.LEDonNOYESCMaintain activation of the controls and checkconnector YV1 for:- 12V voltage- 1A to 1.6A currentNO12VOKReplace the electric wiringharness between electrovalveYV1 and the turntable controlpanelENDYES1A to 1.6AOKYESNOReplace electrovalveYV1Replace the coil ofelectrovalve YV1See FicheC077 or C108ENDEND