Sheet DP018BREAKDOWN DETECTION FLOW CHARTNO TURNTABLE ROTATION MOVEMENT(RIGHT AND / OR LEFT) FROM THE PLATFORM(OR TURNTABLE) CONTROL PANELAFolio 2/3Activate the rotation movement in the emergency mode:-Put the emergency lever in place on the rotation distributionplatform control (YV5)-Activate the lever to the right and left while pressing theemergency control of the safety valve (YV1)MovementOKNOBYES-Activate the rotation switch (SA15)from the turntable panel and check for3V or 9V voltage, depending on themovement direction, at the terminalsof electrovalve YV5Maintain the control activated andcheck for 3V or 9V voltage (dependingon the movement direction) onterminal 512A of the printed circuit.NOVoltageOKYESNOVoltageOKReplace PVG electrovalve YV5See FicheC077Replace the U1moduleSee FicheC058YESENDVoltageOKNORepair the connection or replace theelectric wiring harness between the turntablecontrol panel and electrovalve YV5YESENDENDReplace theprinted circuitSee FicheC063END