Sheet DP027BREAKDOWN DETECTION FLOW CHARTNO PLATFORM ROTATION MOVEMENT(RIGHT AND / OR LEFT)Folio 2/5APress the pedal and activate theplatform rotation switch. Check for 12V voltageat the terminals of the PVG connectorYV2a (YV2b for H14/16, HB40/44J)12VOKYESNO- Open the turntable control panel- Press the pedal and activate the platformrotation switch. Check for 12V voltage on terminal305 (415 for H14/16, HB40/44J) of the printed circuitSee FicheC077Replace the PVGYV2 control head12VOKNOReplace theU1 moduleSee FicheC058ENDYESRepair the connection orreplace the electric wiringharness between the turntablecontrol panel and PVG YV2The faultpersistsYESNOENDReplace theprinted circuitSee FicheC063ENDEND