12.07.2015 Views

PhD Thesis - Energy Systems Research Unit - University of Strathclyde

PhD Thesis - Energy Systems Research Unit - University of Strathclyde

PhD Thesis - Energy Systems Research Unit - University of Strathclyde

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

elow the maximum comfortable temperature <strong>of</strong> around 26°C recommended by bothCIBSE in [6] and ASHRAE in [5]. For the 6 household building, similar settingswere adopted as shown in Table 3.4.Table 3.4 - Control settings for cooling season; 6 Household buildingFloor level/ApartmentZoneHouseholdNo.Occupancy(No. <strong>of</strong>persons)Control time periods(Temperature limits)(‘On’ - ‘Off’)CommentGroundFloorLivingAreaBedroomArea2A + 3A 507.00-08.00 Hours15.00-24.00 Hours(24°C - 21°C)00.00-07.00 Hours(24°C - 21°C)Ground floor isvacant between08.00-15.00HoursMiddleFloorLivingAreaBedroomArea3B + 4A 707.00-24.00 Hours(24°C - 21°C)00.00-07.00 Hours(24°C - 21°C)Middle floor isnever vacantTop FloorLivingAreaBedroomArea4B + 2B 607.00-10.00 Hours13.00-24.00 Hours(24°C - 21°C)00.00-07.00 Hours(24°C - 21°C)Top floor isvacant between10.00-13.00Hours3.1.3 Intermediate seasonThe indoor temperature <strong>of</strong> all apartment zones during the intermediate season, whichcovers the calendar period between the 20 th <strong>of</strong> March and the end <strong>of</strong> May and thebeginning <strong>of</strong> October and the 18 th <strong>of</strong> December, was uncontrolled for the entireduration <strong>of</strong> the period. Although during this calendar period daily morning andafternoon temperatures tend to be in the low 20s [9], temperatures are stillcomfortable enough that no cooling is required. Similarly temperatures during theevening are high enough that no heating is required. No form <strong>of</strong> indoor temperaturecontrol was assumed for any <strong>of</strong> the apartments during this period. The thermaldemand in this case was therefore exclusively due to the hot water demand.3.2 Satisfying the energy demand - The micro-trigeneration plantconfigurationBefore describing how the micro-trigeneration plant was modelled and controlled tosatisfy the energy demands <strong>of</strong> the building, Section 3.2.1 elaborates on the building95

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!