12.07.2015 Views

Untitled - Uhlenbrock

Untitled - Uhlenbrock

Untitled - Uhlenbrock

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MARCoComputation of the command value for the change of locomotive special functions (LF)LF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12Value 1 2 4 8 16 32 64 128 256 512 1024 2048 4096Selection x xCalculatedvalue forLNCV 30Sum 1 32 33Computation of the command option for the change of locomotive special functionsOpt No. Description Selection value sum1 Do not evaluate driving direction X 0 0Driving direction from Track1 to track2 2Driving direction from Track2 to track1 32 Switching function 2 or 3 X 0 0Automatic operation 4-12, 20-28: on arrival at the detector 0Automatic operation 4-12, 20-28: when driving off 43 Switch auxiliary function off 0Switch auxiliary function on 8Change auxiliary function X 16 164 Auxiliary function timed change 325 Switching duration in seconds (max. 31) * 256 * 2566 Position in the sequence (0-4) * 8192 (see Chap. 7.4.6) * 8192Calculated value for LNCV 40 16LNCVs 21, 31 and 41 give the following instruction:All category 2 locomotives (i.e. 20002) switch the light ON (f0) when driving in the directionfrom detector 2 to detector 1.The numerical values for the command value in LNCV 31 and the command option in LNCV41 are shown over the following two tables:Computation of the command value for the change of locomotive special functions (LF)LF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 CalculatedValue 1 2 4 8 16 32 64 128 256 512 1024 2048 4096 value forSelection XLNCV 31Sum 1 1Computation of the command option for the change of locomotive special functionsOpt No. Description Selection Value Sum1 Do not evaluate driving direction 0Driving direction from Track1 to track2 2Driving direction from Track2 to track1 X 3 32 Switching function 2 or 3 X 0 0Automatic operation 4-12, 20-28: on arrival at the detector 0Automatic operation 4-12, 20-28: when driving off 43 Switch auxiliary function off 0Switch auxiliary function on X 8 8Change auxiliary function 164 Auxiliary function timed change 325 Switching duration in seconds (max. 31) * 256 * 2566 Position in the sequence (0-4) * 8192 (see Chap. 7.4.6) * 8192Calculated value for LNCV 41 11LNCVs 22, 32 and 42 give the following instruction:The locomotive address 103 switches f1 (e.g. sound), in driving direction from detector 1 todetector 2. The function is to be switched off again after 16 seconds have elapsed.The numerical values for the command value in LNCV 32 and the command option in LNCV42 arise over the following two tables:34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!