12.07.2015 Views

Untitled - Uhlenbrock

Untitled - Uhlenbrock

Untitled - Uhlenbrock

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MARCoLNCV Description3 Direction in which the automation is active according to LNCV 20 = Automatic active with travel direction from track 1 to track 21 = Automatic active with travel direction from track 2 to track 12 = Automatic active in both travel directions (only stopping point)4 Holding time for shuttle traffic and terminus (automatic functions in setin LNCV 2). Value in seconds.5 Delay period between switching the locomotive’s route and thedeparture of the waiting locomotive applies to all modes set in LNCV 2.Value in seconds.6 Solenoid address of the exit signal for the automatic mode set in LNCV2. In automatic modes 4, 6, 20 and 22 the signal is set by the module;in automatic modes 5, 7-10, 21 and 23-26 the signal is monitoredstopping the train.Note: This signal must always be specified in automatic mode.7 1. Address for solenoid, routes from Intellibox or feedback for thoseAutomatic modes set in LNCV 2. The appropriate instruction is sent, ifthe detector is passed.0 = no address instruction is sent20010 - 20241 = switch an Intellibox route10, 20, 30 - 20000 = solenoid 1, 2, 3 - 2000 set to red/round11, 21, 31 - 20001 = solenoid 1, 2, 3 - 2000 to green/straight set12, 22, 32 - 20482 = feedback address 1, 2, 3 - 2048 - vacant13, 23, 33 - 20483 = feedback address 1, 2, 3 - 2048 - occupied20010-20241 = Intellibox I – Route switching8 2. Address for solenoid, routes in Intellibox or feedback for thoseautomatic mode as set in LNCV 2. See LNCV 7.9 Block speedIf a speed step (2-127) is entered here, then the module in theautomatic modes 4-10 and 20-26 (LNCV 2) can use a 3 detectorsystem. The normal double detector detects the train and reduces itsspeed to the specified value. Detector 2 and 3 are connected inparallel - 2. Detector 3. then brakes the train to speed step 1 (=emergency stop).0 = stop with the locomotive decoder’s-internal delay1 = emergency stop (stop without delay)2-127 = speed step for the slow section10 Block option = options for reporting the change in block status from"occupied" to "vacant", if a train drives out of or through the block.0 = exit signal (LNCV 6) is set to "red" after the block is vacated1-255 = the statue is reported after the specified Value in seconds.257-511 = like previously. Now the Exit signal in LNCV 6 is set to red.Value in seconds + 25611 Automatic operation functions by solenoid address switch on or off.0 = no mechanism influence by the solenoid address1-2000 = solenoid red: MARCo-Receiver is not active or green isactivate12 Train dependent automation = switching automatic functions on or offby train categories.For functions 4-12 and 20-28 as in LNCV 20 = no automatic influence by train categories1-15 = All train categories the except the one entered should influencethe automatic function upon arrival in the track section,101-115 = Only the one entered should influence the automaticfunction upon arrival in the track section.Value SeeRange chapter0-2 7.40-255 7.4.17.4.30-255 7.4.51 2000 7.4.17.4.40-20483 7.4.17.4.50-20483 7.4.17.4.50-127 7.4.20-511 7.4.50-2000 7.4.30-15101-1157.4.479

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!