4. ExampleMARCoBraking at a holding point with two directional trafficIn order to stop a train in either direction at the same place you must use the ancillary circuitas shown, so no more than 2 photo detectors are attached to the receiver input. Control of twosignals with different addresses is however not possible with the circuit indicated here,because in this case the module’s operating mode is ‘direction dependent holding place’ andthe travelling direction is recognized by different detectors. The MARCo-Receiver controls onlyone signal with the solenoid address, which is entered in LNCV6.Basic programming of the LNCVs 0-19LNCV Value Type LNCV Value Type0 1 1. Address (module address) 9 10 Speed before stopping1 0 2. Address 10 2 Block option2 6 Function (mode) 11 0 Solenoid address for on/off Op.3 0 Driving direction 12 0 Category option4 60 Holding time 13 0 Address entry manager5 2 Delay for solenoid switching 15 0 Module configuration6 10 Signal to sets 17 8 Number of receiver addr. bytes7 0 1. Solenoid/feedback address 18 0 Time to next automatic start8 0 2. Solenoid/feedback address 19 1 Startup time95