30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MTL<strong>8000</strong> 2/x System specificationSystem specificationMECHANICALMounting method...................................Flat panel or DIN-railDIN-rail types ................‘Top hat’, 35 x 7.5 mm to EN 50022....................................................or 35 x 15 mm to EN 50022........................................................or G-section, to EN 50035RAILBUS (Backplane)Maximum physical length* of node ..........................6.8 mMaximum number of extender cables ............................3* overall, including backplanes and extender cablesNODE SIZEBIM/Controller typeModule limit8502-BI-DP . . . . . . . . . . . . . . . . . . . . . . . . 32 max.8505-BI-MB . . . . . . . . . . . . . . . . . . . . . . . 32 max.8521-xx-MT . . . . . . . . . . . . . . . . . . . . . . . 64 max.Note: I/O module carriers used with these must conform to the samemodule address limits. See I/O module carrier datasheets for details.ELECTRICALEMC compliance..................................To BS EN 61326:1998Electrical safety ................................................. EN 61010-1ISOLATIONI/O Modules - 2/2Between isolated channels....250 V ac rms (to EN 61010-1)...........................................................(Tested at 2.3 kV ac rms)Channel (any) to Railbus .................................250 V ac rms(Except where stated on individual module specifications)I/O Modules - 2/1Between hazardous area terminals and Railbus ..........60 V ac rmsBetween IS field circuits of separate I/O modules† ...500 V ac rmsBetween any IS field circuit & non-IS field circuit .......250 V ac rmsBetween individual channels of an I/O module ..................................................................refer to individual module specifications† 60 second testENVIRONMENTALAmbient tempOperating, optimum orientation * .....................– 40°C to + 70°C(except where stated in individual module specifications)Operating, non-optimum orientation * ...............– 40°C to + 50°C(except where stated in individual module specifications)Storage..........................................................– 40°C to + 85°C* Optimum orientation is when the carrier is mounted in a verticalplane with field terminals located below the modules.Relative Humidity .....................5 to 95% RH (non-condensing)Ingress Protection .........................IP20 to BS EN60529:1992(Additional protection by means of enclosure)Corrosive atmospheres: Designed to meet ten year service inClass G3 corrosive environment, as defined by ISA StandardSP71.04.Vibration - Storage & TransportEN 60068-2-6(Sinusoidal Vibration)BS2011:Part 2.1(Random Vibration)Vibration - OperatingEN 60068-2-6(Sinusoidal Vibration)BS2011:Part 2.1(Random Vibration)Shock - Storage & TransportEN 60068-2-32Shock - OperatingEN 60068-2-2710-500 Hz.5 g for surface mounting,1 g for DIN-rail mounting20-500 Hz5 g for surface mounting1 g for DIN-rail mounting10-500 Hz.5 g for surface mounting,1 g for DIN-rail mounting20-500 Hz5 g for surface mounting1 g for DIN-rail mounting1 m drop onto flat concrete,30 g peak acceleration with11 ms pulse widthIMPORTANTUsers are strongly recommended to refer to the System Specifier’s Guide (SSG8002) when designing a new systemEUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comJune 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!