8-channel Discrete Output20–265V ac, non-isolated, module powered 8116-DO-AC◆◆◆◆◆◆8 powered outputscontrols solenoids and relayscommon load supply of up to 265V acdiscrete or pulsed outputs1A per channel maximum20–265V ac bussed field power requiredMODULE SPECIFICATIONSee also System SpecificationOUTPUTSNumber of channels ...........................................................8Output voltage range.........................................20–265V acFrequency ..............................................................50 / 60HzON voltage drop.........................................................< 1.2VOFF leakage current ...................................................< 4mASwitched current per channel †Continuous ..........................................................................1A*For < 100ms .........................................................................5AFor < 20ms .........................................................................20AMinimum load current, per channel@ 115V ac.......................................................................11mA@ 230V ac.........................................................................5mA† Stated figures are for operation with unfused field terminal.When operating with 2A fused field terminal (part no. 8604-FT-FU)maximum switched current is 5A inrush for < 10ms pulse width at 0.1%duty cycle and < 10 8 operations.* Limited to 3A per module.‡ Consult MTL for availabilityLLoadNSafe areaor Zone 2/Div 2 hazardous areaChannel 1 of 8µPRailbusN L20 - 265 VacBussed Field PowerCONFIGURABLE PARAMETERSOutput initialisation state .............................predefined valueFail-safe...........................................predefined value/last valueOutput .........................discrete, momentary or continuous pulse‡Pulse width ..........................................................2ms to 130sRESPONSE TIMEResponse time (max.).........2 ms + ½ cycle of mains frequency(From Railbus command to output change)POWER SUPPLIESRailbus (12V) current..........................................75mA (typ.)...........................................................................125mA (max.)Bussed Field Power (voltage) .........................20 to 265V acMECHANICALModule Key Code ..............................................................F1Module width ...............................................................42mmWeight ............................................................................220gFIELD TERMINALField wiring Recommended CompatibleField Terminal Field TerminalGeneral purpose 8604-FT-FU 8602-FT-STFused Standard †Class 1, Div 2 8611-FT-FU 8610-FT-NAor Zone 2 Non-arcing, Non-arcing †hazardous areas Fused† Alternative fusing in the field wiring is recommended if it is not providedin the field terminal.EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!