30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

32-channel Discrete Input24V dc, non-isolated, module-powered8125-DI-DC◆◆◆◆◆up to 32 input channelsfor dry contact switches or proximity detectorspulse counting and latching option24V dc bussed field power requiredline fault detection on all inputsResistors are requiredfor line fault detection1kW9kWSafe areaor Zone 2/Div 2 hazardous areaChannel 1 of 32RegulatorsmPMODULE SPECIFICATIONSee also System SpecificationRailbusINPUTNumber of channels .........................................................32OFF current ...............................................................< 1.2mAON current ............................................................... > 2.1mAShort circuit current.............................................8.6mA (typ.)Output resistance .................................................950Ω (typ.)Open circuit output voltage..............................8.2V dc (typ.)Line fault detectionShort Circuit .............................................................< 100ΩOpen Circuit.............................................................< 50µAInput voltage range without damage .............0 to +12V dcIsolation (channel to Railbus) ..................................250V acInput sampling rate (all 32) .........................................8kHzInput pulse width ...............................................250µS (min.)DI counting frequency without loss.................500Hz (max.)Applicable specification .........................NAMUR, DIN 19234SAFETY24 VdcBussed Field PowerFM non-incendive field wiring parameters (each channel)..................V oc = 8.64V; I sc = 18.5mA; C a = 28µF; L a = 23.6mHPOWER SUPPLIESRailbus (12V) current ................................................< 50mABussed field power ...........................190mA (max.) at 24V dcMECHANICALModule Key Code..............................................................B3Module width ...............................................................42mmWeight ............................................................................185gCONFIGURABLE PARAMETERSInput filter...................................0 to 8.192secs in 250µs stepsPulse counting ..............................................................on/offLatching.........................................................................on/offRESPONSE TIMEInput module scan time ...............................................< 1ms(Inputs sampled at 8kHz and processed every 1ms)FIELD TERMINALField wiring Recommended CompatibleField Terminal Field TerminalGeneral purpose 8617-FT-NI 8619-FT-MT16/30 channel DI 44-pin MTAClass 1, Div 2 8617-FT-NI 8619-FT-MTor Zone 2 16/30 channel DI 44-pin MTAhazardous areasEUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!