8-channel Discrete Output2–60V dc, non-isolated, module powered 8115-DO-DC◆◆◆◆◆◆8 powered outputscontrols solenoids and relayscommon load supply of up to 60V dcdiscrete or pulsed outputs1A per channel switched current2–60V dc bussed field power requiredMODULE SPECIFICATIONSee also System SpecificationOUTPUTSNumber of channels ..........................................................8Output voltage range ............................................2–60V dcON voltage drop ................................................0.25V (max.)OFF leakage current..........................................1.0mA (max.)Switched current per channel †Continuous* ..........................................................................1AFor < 100 ms ........................................................................4AFor < 20 ms ..........................................................................6ACONFIGURABLE PARAMETERSOutput initialisation state .............................predefined valueFail-safe...........................................predefined value/last valueOutput ........................discrete, momentary or continuous pulse ‡Pulse width ..........................................................2ms to 130s† The total instantaneous switched current for the module should not exceedthe following:10A for < 100ms18A for < 20msFor a way to increase these limits using high-current relays see TechnicalSupport Note TSN110 on the MTL web site.+Load–Safe areaor Zone 2/Div 2 hazardous areaChannel 1 of 8RailbusRESPONSE TIMEResponse time........................................................1ms (max.)(From Railbus command to output change)POWER SUPPLIESRailbus (12V) current..........................................45mA (typ.)......................................................................70mA (max.)Bussed Field Power ............................................2 to 60V dcMECHANICALModule Key Code ..............................................................B6Module width ..............................................................42mmWeight ............................................................................200gµP2 - 60 VdcBussed Field Power* Limited to 6A per module unless using high current relay option‡ Consult MTL for availabilityFIELD TERMINALField wiring Recommended CompatibleField Terminal Field TerminalGeneral purpose 8604-FT-FU 8602-FT-STFused Standard †Class 1, Div 2 8611-FT-FU 8610-FT-NAor Zone 2 Non-arcing, Non-arcing †hazardous areas FusedSee also the 8618-FT-MT field terminal for custom termination options.† Alternative fusing in the field wiring is recommended if it is not providedin the field terminal.EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!