30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Module carriersIS 4-module carrier8720-CA-04◆◆◆◆◆◆◆◆32-slot address bus*accepts up to four 2/1 I/O modules andfield terminalsprinted wiring boardrugged polycarbonate mouldingDIN rail or panel mountingcarries control signals and data on Railbusdistributes DC power to modulesisolated earthing bar for cable screens/shieldsCARRIER SPECIFICATIONSee also System SpecificationHAZARDOUS AREA APPROVALSLocation of node.........Class 1, Div 2, Groups A, B, C, D T4 hazardous location or......Zone 2, IIC T4 hazardous locationLocation of field wiring.........Class 1, Div 1, Groups A, B, C, D T4 hazardous location or......Zone 1 /Zone 0, IIC T4 hazardous locationField terminals accepted ............................................IS onlyI/O modules accepted ........................................... 2/1 onlyELECTRICALRailbus connectors....................................male in, female outModule address range.................................................1–32Earth leakage detectionA 4-pin connector is provided at the top/rear of the carrier for wiringthe individual modules to earth leakage detectors, e.g. MTL2220.(Refer to MTL for earth leakage detection support within I/Omodules.)MATERIALSCarrier moulding......................Modified poly-phenylene oxidePrinted wiring board...........Epoxy resin woven glass laminateENVIRONMENTALAmbient tempOperating ......................................................– 40°C to + 70°CStorage..........................................................– 40°C to + 85°CRelative Humidity .....................5 to 95% RH (non-condensing)Vibration and Shock.................See System specification sheetMECHANICALDimensions...............................178 (w) x 170 (d) x 22 (h) mmWeight..........................................................................350 gMounting methods ...............................Flat panel or DIN railDIN-rail types...... ‘Top hat’ 35 x 7.5 mm rail or 35 x 15 mm rail to EN 50022........................................................G-section rail to EN 50035* Must not be mixed with 64-slot address bus carriersMODULE NUMBER1 2 3 4EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comJune 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!