30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8-channel Discrete Input24V dc, isolated, sinking8109-DI-DC◆◆◆◆8 discrete isolated inputs24V dc field voltage sourcesuser definable input thresholdpulse counting optionSafe areaor Zone 2/Div 2 hazardous areaMODULE SPECIFICATIONSee also System SpecificationChannel 1 of 8µPINPUTSNumber of channels ...........................................................8OFF voltage.............................................................< 3.2V dcON voltage .............................................................> 11V dcWetting current ..................................6.3mA (nom.) @ 24V dcMinimum pulse width detected .....................................3msMaximum switching frequency (no-filtering)...........200HzMaximum voltageInput ..............................................................................30V dcReverse input................................................................– 25V dcCONFIGURABLE PARAMETERSSelectable input filter ........................fast, slow or user defined(User defined permits 0 to 512ms values in 2ms steps)Latch inputs.....................................................enable /disableLatch polarity.................................latch on high / latch on lowPulse counting ................................................enable /disableRESPONSE TIMEI/O response timeField event to new data available on Railbus.................3ms (max.)24VRailbusDCSAFETYFM non-incendive field wiring parameters (each channel)...........................V max = 30V; I max = 100mA; C i = 0µF; L i = 0mHPOWER SUPPLIESRailbus (12V) current..........................................35mA (typ.).............................................................................55mA (max.)Bussed Field Power .............................................not requiredMECHANICALModule Key Code..............................................................B2Module width ...............................................................42mmWeight ............................................................................170gFIELD TERMINALField wiring Recommended CompatibleField Terminal Field TerminalGeneral purpose 8602-FT-ST 8604-FT-FUStandard †FusedClass 1, Div 2 8610-FT-NA 8611-FT-FUor Zone 2 Non-arcing † Non-arcinghazardous areasFusedSee also the 8618-FT-MT field terminal for custom termination options.† External fusing of the Field Power supply is recommended in order toprotect the field wiring.EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!