Field terminals◆◆◆◆◆range of field terminalsstandard, fused, loop-disconnect & MTAsblue moulding for IS field wiringTHC and RTD versions availabletag strip on all screw-clamp field terminalsSPECIFICATIONSee also System SpecificationHAZARDOUS AREA APPROVALSLocation of field terminal...Zone 2, IIC, T4 hazardous area orClass 1, Div 2, Groups A–D, T4 hazardous locationLocation of I/O field wiringFor 860x-FT-xx and 861x-FT-xx...Zone 2, IIC, T4 hazardous......area or Class 1, Div 2, Groups A–D, T4 hazardous locationFor 862x-FT-IS .........................Zone 0, IIC hazardous area orDiv 1, Groups A–D hazardous locationELECTRICALRated voltage ..........................................................250V acMaximum current per I/O channel................................3AFuse rating (where fitted)....................................................2AConductor size ..................................................0.14–2.5mm 2MECHANICALMaterial ....................................Modified Poly-Phenylene OxideDimensions - approx (including tagging strip)8617-FT-NI and 8623-FT-IS................42 (w) x 88 (d) x 61 (h) mmOthers...........................................42(w) x 88 (d) x 39.5 (h) mmWeights (typical - including tagging strip)Unfused type (except THC & RTD) .........................................78gFused type (including fuses) ..................................................86gTHC type............................................................................70gRTD type ..........................................................................106g8617-FT-NI and 8623-FT-IS (16-channel) ..............................106gSee also datasheets for 8618-FT-MT and 8619-FT-MTPART NUMBERSGENERAL PURPOSE FIELD WIRINGField terminal descriptionPart numberStandard8602-FT-STFused8604-FT-FUTHC8605-FT-TCRTD8606-FT-RT4-wire transmitter8615-FT-4W16/30-channel DI8617-FT-NI16-pin Mass Termination Assembly 8618-FT-MT44-pin Mass Termination Assembly 8619-FT-MTZONE 2/DIV2 FIELD WIRING APPLICATIONSField terminal descriptionPart numberTHC8605-FT-TCRTD8606-FT-RTNon-incendive*8601-FT-NINon-incendive, fused*8603-FT-FUNon-arcing, standard*8610-FT-NANon-arcing, fused*8611-FT-FU4-wire transmitter8615-FT-4W16/30-channel DI8617-FT-NI16-pin Mass Termination Assembly 8618-FT-MT44-pin Mass Termination Assembly 8619-FT-MTZONE 1, 0/DIV 1 (IS) FIELD WIRING APPLICATIONSField terminal descriptionPart numberIS, standard8621-FT-ISIS, loop-disconnectIS, 16-channel DIIS, 8-channel DI, loop-disconnectIS, THCIS, RTD8622-FT-IS8623-FT-IS8624-FT-IS8625-FT-IS8626-FT-ISADDITIONAL COMPONENTSDescriptionSwitch/Prox. detector wiring panel2A Fuse pack (10 in pack)Loop-disconnect links (10 in pack)Part Number8650-FT-PX8401-FU-2A8405-LK-ZE*Refer to 2/2 I/O module data sheets for recommended non-incendive or nonarcingfield terminal type in Zone 2 and Division 2 applications.EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comJan 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!