30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4-channel Analog InputThermocouple and mV8105-TI-TC◆◆four thermocouple or mV* input channelscold junction compensationSafe areaor Zone 2/Div 2 hazardous areaMODULE SPECIFICATIONSee also System SpecificationOtherchannelsINPUTSMUXA/DNumber of channels ...........................................................4THCs types................B,E,J,K,N,R,S, or T to EN 60584-2, IEC584-2, BS4937;............................................................................W3 and W5.mVChannel 1 of 4CJµPRailbusInput type Range Overall accuracymV 0 to + 120mV ±0.1% of span (+10 to +40 ° C)Basic THC accuracy (BTA)...............25 ° C ±0.05% of THC span.........................................+10 ° C to +40 ° C ±0.1% of THC span.........................................–40 ° C to +70 ° C ±0.3% of THC spanCold junction compensation error† 80dB @ 50/60HzSeries mode rejection..............................> 40dB @ 50/60HzMaximum input voltage.............................................± 4.0VCommon mode voltage between channels ....± 4.5V (max.)Isolation (any channel to Railbus) ....................250V ac rmsOpen circuit bleed current..............................± 0.5µA (nom.)CONFIGURABLE PARAMETERS±0.2% of span (–40 to +70 ° C)THC: B 0 to + 1820°C < 600°C 1.5°C + BTA≥ 600°C 0.45°C + BTAE – 270 to + 1000°C 0.3°C + BTAJ – 210 to + 1200°C 0.3°C + BTAK – 270 to + 1372°C 0.3°C + BTAN – 270 to + 1300°C 0.3°C + BTAR – 50 to + 1767°C 0.6°C + BTAS – 50 to + 1767°C 0.4°C + BTAT – 270 to + 400°C 0.3°C + BTAW3 0 to + 2320°C 0.6°C + BTAW5 0 to + 2320°C 0.4°C + BTASensor type .......................................................user selectableInput dead zone (hysteresis)......................user defined valueSelectable input filtering ...off /2 reading avge./running avge.Drive on open circuit fault....... disabled /upscale /downscaleAlarms.................................................................high and lowChannel status.................................................active/ inactive* Consult MTL for availability† C J compensation located in recommended field terminalRESPONSE TIMESSignal change to availability on Railbus.............................................................................120ms (min.)............................................................................420ms (max.)O/C sensor detection....................................................≤ 10sSAFETYFM non-incendive field wiring parameters (each channel) ..................V oc = 10.5V; I sc = 3.6mA; C a = 14.9µF; L a = 1000mHPOWER SUPPLIESRailbus (12V) current.........................................150mA (typ.)...........................................................................200mA (max.)Bussed Field Power .............................................not requiredMECHANICALModule Key Code .............................................................C1Module width ...............................................................42mmWeight ............................................................................200gFIELD TERMINALField wiring Recommended CompatibleField Terminal Field TerminalGeneral purpose 8605-FT-TC –THCClass 1, Div 2 8605-FT-TC –or Z one 2THChazadous areaEUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!