Bus interface modulesProfibus protocolMODULE SPECIFICATIONSee also System SpecificationLAN INTERFACELAN protocol................................PROFIBUS-DP (to EN50170)Transmission rates ........9.6, 19.2, 93.75, 187.5, 500 kbaud..............................................................and 1.5 and 6 MbaudMaximum bus segment length (metres) depends upon speed..........Speed 9.6 19.2 93.75 187.5 500 1500 6000(kbaud)Max. 1200 1200 1200 1000 400 200 100length(Note: Table applies to cables with an impedance of 135 -165 Ωand a capacitance per unit length that does not exceed 30 pF/m.)Transmission standard..............................................RS 485Isolation(LAN to Railbus to Power Supply) ......................................500 VAction on software malfunction .........modules go to failsafeI/O & DIAGNOSTIC DATADP Data frame.................... Size configurable up to 244 bytesInput data, including Status word (2 bytes) .............................................................................................244 bytes maxOutput data, including Control word (2 bytes) ........................................................................................244 bytes maxTotal Input plus Output data ........................296 bytes maxDiagnostic telegram ...............................................78 bytesLED INDICATORSPower fail Power OK –8502-BI-DPPower (green)OFF ON FlashingFault (red)OFF ON FlashingNormal Failsafe or fault –Comm (yellow)OFF ON FlashingInternal Internal On power upComms. Failure Comms. OKLAN A (yellow)OFF ON FlashingPower OFF LAN activity Slow flash = no LAN activeConfig, (yellow)OFF ON FlashingNot defined Configurator Configurator(i.e. error) connected not connectedRailbus (yellow)OFF ON FlashingRailbus Fault Railbus OK –CONFIGURATIONThe BIM can be configured using MTL’s 8455-SW-CF softwarerunning on a PC, by parameterisation from a Profibus configurator orby transfer of a configuration from the 8510-NS-MO Node ServicesModule. The 8510 also has an autoconfiguration option.Address setting.................................Software settable in BIM,...................................by Profibus “Set Slave Address” command..............................or by switch setting on 8510-NS--MO modulePOWER SUPPLIESRailbus (12V) current .....................................420 mA ( typ.)...........................................................520 mA ( max.@ -40 °C)MECHANICALModule width .............................................................63 mmWeight (approx.).........................................................350 gEUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comJune 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!