8-channel Discrete Input230V ac, isolated, sinking8113-DI-AC◆◆◆◆8 discrete isolated inputs230V ac field voltage sourcesuser definable input thresholdpulse counting optionSafe areaor Zone 2/Div 2 hazardous areaMODULE SPECIFICATIONSee also System SpecificationChannel 1 of 8µPINPUTSNumber of channels ...........................................................8OFF voltage..............................................................< 68V acON voltage.............................................................> 168V acWetting current ...................................1mA (nom.) @ 230V acMax. input voltage...................................................265V acFrequency ..............................................................50 / 60HzCONFIGURABLE PARAMETERSSelectable input filter ........................fast, slow or user defined(User defined permits 0 to 512ms values in 2ms steps)Latch inputs.....................................................enable /disableLatch polarity.................................latch on high / latch on lowPulse counting ................................................enable /disableL230VACNRailbusPOWER SUPPLIESRailbus (12V) current..........................................40mA (typ.).............................................................................60mA (max.)Bussed Field Power .............................................not requiredMECHANICALModule Key Code ..............................................................E5Module width ...............................................................42mmWeight ............................................................................170gRESPONSE TIMEI/O response time ...............................................33ms (max.)(Field event to new data available on Railbus)FIELD TERMINALField wiring Recommended CompatibleField Terminal Field TerminalGeneral purpose 8602-FT-ST 8604-FT-FUStandard †FusedClass 1, Div 2 8610-FT-NA 8611-FT-FUor Zone 2 Non-arcing † Non-arcing,hazardous areasfused† External fusing of the Field Power supply is recommended in order toprotect the field wiring.EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!