30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8-channel Analog Output4–20mA8104-AO-IP◆◆8 single-ended outputs4–20mASafe areaor Zone 2/Div 2 hazardous area◆for I/P converters and remote indicators, etc◆open circuit detection is provided on each channelRegulator◆24V dc bussed field power requiredOtherchannelsMUXD/AMODULE SPECIFICATIONSee also System SpecificationOUTPUTSNumber of channels .......................................8, single-endedNominal signal range (span) ...............................4 to 20mAFull signal output range........................................1 to 23mAOpen loop detection threshold .......................0.7 ± 0.25mAOutput compliance.................................20mA at 21.6V dc supply (into 700Ω load)Accuracy (over temp range) ........................± 0.25% of spanOutput ripple.................................................< 0.02% of spanResolution ....................................................................12 bitsIsolationany channel to Railbus ...................................................100V acCONFIGURABLE PARAMETERSInitialisation state..........................................predefined valueDrive on fail-safe .........................predefined value / last valueChannel status................................................active / inactivePI4-20mAChannel 1 of 8Railbus24 VdcBussed Field PowerRESPONSE TIMEResponse timeFrom Railbus command to output change ....................25ms (max.)SAFETYFM non-incendive field wiring parameters (each channel) ....................V oc = 28.7V; I sc = 33mA; C a = 0.17µF; L a = 11.0mHPOWER SUPPLIESRailbus (12V) current.......................................100mA (typ.)...........................................................................150mA (max.)Bussed Field Power.................300mA (max.) @ 24V dc ±10%Quiescent current .........................................................60mAMECHANICALModule Key Code .............................................................A4Module width ...............................................................42mmWeight ............................................................................200gµPFIELD TERMINALField wiring Recommended CompatibleField Terminal Field TerminalGeneral purpose 8602-FT-ST 8604-FT-FUStandardFusedClass 1, Div 2 8601-FT-NI 8603-FT-FUor Zone 2 Non-incendive Non-incendive,hazardous areasfusedSee also the 8618-FT-MT field terminal for custom termination options.EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!