30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MTL<strong>8000</strong>-2/x Series - OverviewMTL<strong>8000</strong> with generalpurpose field wiringMany industry applications do not presentan explosion risk from gas or dust hazards.In others, the environment may be classifiedas a Zone 2 or Division 2 hazardous area,where flammable material is expected tooccur only in abnormal conditions. For bothof these the 2/2 system provides effectivedistributed I/O for process control.MTL<strong>8000</strong> supports a full range of I/O moduletypes covering inputs and outputs forboth analog and discrete circuits. The nodecan be mounted out on the plant in a suitableenclosure providing protection againstthe environment. Figure 3 shows a nodecontaining all the key components: a BusInterface Module, PSU modules (including aredundant one), I/O modules on carriersand a pair of carrier-extenders linked withan extension cable.local18–36 V DCpowerSystem powersupplyOtional redundantsystem powersupply moduleCarrierextender(LH)Bus InterfaceModule4-module carrier(General purpose p orZone 2/Div 2)(General purpose p orZone 2/Div 2)Bussed Field PowerBussed Field Power8-module carrier(General purpose p orZone 2/Div 2)(General purpose p orZone 2/Div 2)Carrierextender(RH)To maximum of 32I/O modulesD.C. power linkto otherextenderMTL<strong>8000</strong> with intrinsicsafety field wiringThe MTL<strong>8000</strong> Process I/O System is capableof supporting I/O modules with intrinsicsafety (IS) field wiring, for connection tocertified or ‘simple apparatus’ field devicesin Division 1 or Zone 0 hazardous areas(see Figure 4). A range of I/O module typeswith IS field circuits for industrystandardDI, DO, AI and AO applications issupported.I/O modules with built-inprotectionAll voltage and current-limiting componentsrequired for IS protection are incorporatedwithin the I/O module housings, so noexternal, add-on zener barriers or galvanicisolators are necessary. IS field terminalsare distinguished from other types by bluecolouring of the terminal housing. A uniqueand sophisticated mechanical keyingmechanism prevents modules with differentprotection techniques from being interchanged,so that potentially explosive ordamaging conditions cannot occur.Integrated power suppliesPower for IS I/O modules is derived fromintegrated, modular power supply units.Each power unit is capable of supplyingbetween eight and twenty I/O modules,depending on the I/O type and mix.Optional power supply redundancy issupported by means of an additional,redundant supply unit connected in an‘n+1’ arrangement. In applications withmixed IS and non-IS field wiring, the fullfacilities of the ‘Bussed Field Power’ regimeare retained for the non-IS part of the system.Figure 3 MTL<strong>8000</strong> nodeLocal12 V dcpowerBIMCarrierCarrier(LH)BusInterfaceModuleLANterminalsRailbus IsolatorModule andCarrierLocal18–36V dcpower4-module carrier(IS field wiring)[EEx ia]I/O modulepower supplyLocal18–36V dcI/O modulepower supply8-module carrier (IS field wiring)[EEx ia]8-module carrier(IS field wiring)[EEx ia]Figure 4 MTL<strong>8000</strong> node with IS field wiringIn nodes populated only with IS I/Omodules, a separate system power supplymodule provides power for the Bus InterfaceModule and ‘node services’. Redundancyof this supply is also supported.CarrierExtender(RH)DINrailExtendercablesLocal18–36V dcpowerTo maximum of32 I/O modulesOptional n+1redundantI/Omodule powersuppl yMTL Power Court, Luton, Bedfordshire, England LU1 3JJTel: +44 (0)1582 723633 Fax +44 (0)1582 422283E-mail: enquiry@mtl-inst.com Web site: http://www.process-io.comSept 2002

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!