30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8-channel Analog Input1–5V 8119-VI-05◆◆8 single-ended input channelsnon-incendive field circuitsSafe areaor Zone 2/Div 2 hazardous area◆1–5V inputs◆open circuit and short circuit detection◆24V dc bussed field power requiredOtherchannelsMUXA/DChannel 1 of 8MODULE SPECIFICATIONSee also System Specification1–5VDCµPRailbusINPUTSNumber of channels .......................................8, single-endedNominal signal range (span) ....................................1 to 5VFull signal range ..............................................0.19 to 5.64VInput impedance ............................................................2MΩOut of range alarmLower threshold..............................................................< 0.19VUpper threshold .............................................................> 5.64VAccuracy (over temp range) ..........................± 0.1% of spanResolution ....................................................................16 bitsRepeatability ....................................................0.05% of spanIsolation (any channel to Railbus) ..........................100V ac(between channels)..............................................................noneCONFIGURABLE PARAMETERSAlarms .....................................high, high-high, low and low-lowAlarm deadband (hysteresis) ....................user defined valueInput filter time constant ............................user defined valueInput dead zone ..........................................user defined valueDrive on failsafe....................... disabled /upscale /downscaleChannel status................................................ active /inactive24 VdcBussed Field PowerRESPONSE TIMESignal change to availability on Railbus ..........27ms (max.)SAFETYFM non-incendive field wiring parameters (each channel) ....................V oc = 28.7V; I sc = 33mA; C a = 0.17µF; L a = 11.0mHPOWER SUPPLIESRailbus (12V) current.......................................100mA (typ.)...........................................................................150mA (max.)Bussed Field Power................. 60mA (max.) at 24V dc ± 10%MECHANICALModule Key Code .............................................................A1Module width ...............................................................42mmWeight ............................................................................200gFIELD TERMINALSField wiring Recommended CompatibleField Terminal Field TerminalGeneral Purpose 8615-FT-4W –4-wire transmitterClass 1, Div 2 8615-FT-4W –or Zone 24-wire transmitterhazardous areaSee also the 8618-FT-MT field terminal for custom termination options.EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.comOct 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!