30.07.2015 Views

8000 Zone2.pdf

8000 Zone2.pdf

8000 Zone2.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MTL<strong>8000</strong> 2/x System specification2/1 system approvals for mounting and field wiringStandardApproved forPart numbers & descriptionsI/O modulesprEN50021 & EN50021 1Zone 2installationsATEX CategoryII 3 GEUROPE USA (FM) CANADA (CSA)EN50014:1997 & EN50020 5 :1994IS field wiringATEXCategoryII [1] GClass No.3611Div 2installationNon-incendiveapparatussuitable forinstallation inClass 1, Div 2,Grps A-DClass No.3610IS fieldwiringIS fieldterminalsfor Classes,I,II,III,Grps A-GCAN/CSA-E79-15-95Div 2installationnon-sparkingapparatussuitable forinstallation inClass 1,Zone 2/Div 2,Grp IICCAN/CSA-E79-11-95IS fieldwiring forClass I,Zones 0,1,Grp IIC8201-HI-IS 8-channel, 2000 152423-1000846XAI, 4-20 mA with HART EEx n L IIC T4 MTL99ATEX8201 [EEx ia]IIC BAS98ATEX 7207U 3001345 /Ex n A[ia] IICT48202-HO-IS 8-channel,AO, 4-20mA with HART EEx n L IIC T4 MTL01ATEX8202X [EEx ia]IIC BAS01ATEX 7185U 30013458204-AO-IS 8-channel, 2000 152423-1000846XAO, 4-20 mA EEx n L IIC T4 MTL99ATEX8204 [EEx ia]IIC BAS98ATEX 7205U 3001345 /Ex n A[ia] IICT48205-TI-IS 8-channel,THC/mV input EEx n L IIC T4 MTL00ATEX8205X [EEx ia]IIC BAS99ATEX 7316U 3001345 TBA8206-TI-IS 8-channel,RTD input EEx n L IIC T4 MTL00ATEX8206 [EEx ia]IIC BAS99ATEX 7316U 3001345 TBA8215-DO-IS 4-channel, DO, 2000 152423-1000846Xsolenoid driver, IIC gas groups EEx n L IIC T4 MTL99ATEX8215 [EEx ia]IIC BAS98ATEX 7204U 3001345 /Ex n A[ia] IICT48220-DI-IS 16-channel, 2000 152423-1000846XDI, switch/proximity detector EEx n L IIC T4 MTL99ATEX8220 [EEx ia]IIC BAS98ATEX 7206U 3001345 /Ex n A[ia] IICT48223-PI-IS 2-channel,pulse/frequency input EEx n L IIC T4 MTL02ATEX8223X [EEx ia]IIC BAS00ATEX 7202U 3008078230-AI-IS 8-channel,AI, 0-10V/potentiometer EEx n L IIC T4 MTL02ATEX8230X [EEx ia]IIC BAS01ATEX 7346U 3011951FieldTerminals8621-FT-IS IS standard See note 6 [EEx ia] BAS98ATEX 7211U 3001345 2000 152423-1000846X8622-FT-IS IS loopdisconnect See note 6 [EEx ia] BAS98ATEX 7211U 3001345 2000 152423-1000846X8623-FT-IS IS 16-channel See note 6 [EEx ia] BAS98ATEX 7211U 3001345 2000 152423-1000846X8624-FT-IS IS 16-channel,DI, loop disconnect See note 6 [EEx ia] BAS98ATEX 7211U 3001345 2000 152423-1000846X8625-FT-IS IS THC See note 6 [EEx ia] BAS98ATEX 7211U 3001345 2000 152423-1000846X8626-FT-IS IS RTD See note 6 [EEx ia] BAS98ATEX 7211U 3001345 2000 152423-1000846XRailbusisolatorCode Certificate Nos. Code Certificate Nos. Certificate Nos. Certificate Nos.8922-RB-IS Railbus 2000 152423-1000846Xisolator module EEx n L IIC T4 MTL99ATEX8922 [EEx ia] BAS98ATEX 7208U 3001345 / Ex n A IIC T4Powersupply8920-PS-DC IS Power 2000152423-1000846Xsupply,18-36 V dc input EEx nV IIC T4 MTL99ATEX8920 4 [EEx ia] BAS98ATEX 7209U 3001345 / Ex n A IIC T4Note 1 Applies to railbus interfaceNote 2 The railbus interface and I/O field wiring are covered by a single certificate. The railbus interface code is ExnA.Note 3 The railbus interface and I/O field wiring are covered by a single certificate and no distinction is made between non-incendive and non-arcingrailbus interface connections.Note 4 EN50021 was available only in draft form when this apparatus was certified. When EN50021 was finally published, the designationEEx nV had been changed to EEx nA for non-arcing apparatus. EEx nV is equivalent to EEx nA.Note 5 BASEEFA node certificate no BAS98ATEX 7202. BASEEFA system certificate no. Ex98E2203.Note 6 These products are listed in the document MTL<strong>8000</strong>-1 ‘ATEX Documentation for ancillary components used with the MTL<strong>8000</strong> Zone 2 System’.For the latest certification information visit: http://www.mtl-inst.com/certs_1.nsfEUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997E-mail: enquiry@mtl-inst.comWeb site: www.mtl-inst.comJune 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!