Chapter 3: <strong>Teradata</strong> T<strong>Pump</strong> Commands<br />

BEGIN LOAD<br />

Syntax Element<br />

frequency<br />

DATAENCRYPTION<br />

ON/OFF<br />

Description<br />

The interval in minutes between check pointing operations. Specify an<br />

unsigned integer from 0 through 60, inclusive.<br />

To specify a CHECKPOINT frequency of less than or equal to 60, a<br />

checkpoint is recorded at the specified frequency, in minutes.<br />

To specify a CHECKPOINT frequency of more than 60, <strong>Teradata</strong> T<strong>Pump</strong><br />

terminates the job.<br />

Specifying a CHECKPOINT frequency of zero bypasses all checkpoint<br />

functions. <strong>Teradata</strong> T<strong>Pump</strong> does not do checkpoint operations at all,<br />

which is different from <strong>Teradata</strong> Tools and Utilities 07.00 and earlier.<br />

The <strong>Teradata</strong> T<strong>Pump</strong> job will not be re-startable once data loading has<br />

begun.<br />

If a CHECKPOINT frequency is not specified, check pointing occurs<br />

every 15 minutes by default.<br />

Whether specified or not, checkpoints are written at the end of each<br />

data input source.<br />

Note: Checkpoints should not be set for an FDL-compatible INMOD<br />

routine with the FOR, FROM, or THRU options. When an<br />

FDL-compatible INMOD routine is used with the FOR, FROM, or<br />

THRU options, <strong>Teradata</strong> T<strong>Pump</strong> terminates and an error message<br />

appears if the checkpoint frequency is other than zero.<br />

Keyword to encrypt import data and the request text during the<br />

communication between <strong>Teradata</strong> T<strong>Pump</strong> and <strong>Teradata</strong> <strong>Data</strong>base.<br />

If ON, the encryption will be performed. If DATAENCRYPTION is not<br />

specified, the default is OFF.<br />

The "-y" runtime parameter applies the encryption to all connected<br />

sessions, which include the control session and the load sessions. This<br />

option only applies the encryption to the load sessions, which are the<br />

sessions specified by the SESSIONS keyword in the BEGIN LOAD<br />

command, and overrides the "-y" runtime parameter when OFF is<br />

explicitly specified. For example, assuming the PARTITION command<br />

is not used in the job, when "-y" runtime parameter is specified with the<br />

job and DATAENCRYPTION OFF is specified in the script, the<br />

encryption will only apply to the control session. Similarly, assuming<br />

the PARTITION command is not used in the job when "-y" runtime<br />

parameter is not specified with the job, and DATAENCRYPTION ON is<br />

specified in the script, the encryption will apply to all load sessions but<br />

not the control session.<br />

When the PARTITION command is used, the encryption setting<br />

explicitly specified in the PARTITION command will override the<br />

setting of this option over the sessions defined by the PARTITION<br />

command.<br />

100 <strong>Teradata</strong> <strong>Parallel</strong> <strong>Data</strong> <strong>Pump</strong> Reference