Chapter 4: Troubleshooting<br />

Error Messages<br />

Table 29: <strong>Teradata</strong> T<strong>Pump</strong> Error Conditions (continued)<br />

Error<br />

Description<br />

2817 Activity count greater than one for <strong>Teradata</strong> T<strong>Pump</strong> UPDATE/DELETE. This error occurs<br />

if MARK EXTRA UPDATE/DELETE ROWS is specified and an activity count greater than<br />

one was seen. In this case, the error table row is inserted, but the corresponding UPDATE/<br />

DELETE also completes.<br />

2818 Activity count zero for <strong>Teradata</strong> T<strong>Pump</strong> UPDATE or DELETE. This error occurs if MARK<br />

MISSING UPDATE/DELETE ROWS is specified and an activity count of zero was seen.<br />

2844 Journal image is longer than maximum.<br />

2893 Right truncation of string data.<br />

3535 A character string failed conversion to a numeric value.<br />

3564 Range constraint: Check error in field%TVMID.%FLDID.<br />

3577 Row size overflow.<br />

3578 Scratch space overflow.<br />

3604 Cannot place a null value in a NOT NULL field.<br />

3751 Expected a digit for the exponent.<br />

3752 Too many digits in exponent.<br />

3753 Too many digits in integer or decimal.<br />

3754 Numeric precision error.<br />

3755 Numeric overflow error.<br />

3756 Numeric divided-by-zero error.<br />

3757 Numeric stack overflow error.<br />

3758 Numeric stack underflow error.<br />

3759 Numeric illegal character error.<br />

3996 Right truncation of string data.<br />

5317 Check constraint violation.<br />

5326 Operand of EXTRACT function is not a valid data type or value.<br />

5410 Invalid TIME literal.<br />

5411 Invalid TIMESTAMP literal.<br />

5991 Error during plan generation.<br />

6705 Illegally formed character string was encountered during translation.<br />

6706 The string contains an untranslatable character.<br />

6996 Invalid conversion or assignment operation on Period.<br />

198 <strong>Teradata</strong> <strong>Parallel</strong> <strong>Data</strong> <strong>Pump</strong> Reference