25.09.2015 Views

Teradata Parallel Data Pump

Teradata Parallel Data Pump Reference - Teradata Developer ...

Teradata Parallel Data Pump Reference - Teradata Developer ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 2: Using <strong>Teradata</strong> T<strong>Pump</strong><br />

Program Considerations<br />

Table 15: Predefined System Variables<br />

System Variable<br />

&SYSDATE<br />

&SYSDATE4<br />

&SYSDAY<br />

&SYSDELCNT[n}<br />

&SYSETCNT[n}<br />

&SYSINSCNT[n}<br />

&SYSJOBNAME<br />

&SYSOS<br />

&SYSRC<br />

&SYSRCDCNT[n]<br />

Description<br />

8-character date format yy/mm/dd<br />

10-character date format yyyy/mm/dd<br />

3-character day of week: MON TUE WED THU FRI SAT SUN<br />

Number of rows deleted from all the target tables of Import n. If n is not<br />

specified, it gives the count of deletes done to all the target tables for all<br />

imports. The maximum value of n is 4.<br />

Number of records inserted into the error table for import n. If n is not<br />

specified, it gives the total count of all the records inserted into the error<br />

table for all imports. The maximum value of n is 4.<br />

Number of rows inserted into all the target tables for import n. If n is not<br />

specified, this variable gives the total inserts done to all the target tables<br />

for all imports. The maximum value of n is 4.<br />

Up to 16 characters (ASCII or EBCDIC) in length, in whichever<br />

character set is appropriate.<br />

If &SYSJOBNAME is not set using the NAME command, it defaults to<br />

MYYYYMMDD_hhmmss_lllll, where<br />

M = macro<br />

YYYY = year<br />

MM = month<br />

DD = day<br />

hh = hour<br />

mm = minute<br />

ss = second<br />

lllll = is the low-order 5 digits of the logon sequence number returned by<br />

the database from the .LOGON command.<br />

Client operating system:<br />

• UNIX<br />

• HP-UX<br />

• IBM-AIX<br />

• Win32<br />

• Linux<br />

• For z/OS:<br />

VS1<br />

z/OS<br />

z/OS /SP<br />

z/OS /ESA<br />

Completion code from last response by <strong>Teradata</strong> <strong>Data</strong>base.<br />

Total number of records read for import n. If n is not specified, it gives<br />

the total records read for all imports.<br />

<strong>Teradata</strong> <strong>Parallel</strong> <strong>Data</strong> <strong>Pump</strong> Reference 59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!