Appendix A A-89<br />

MB FIELD<br />

DRAFT - Working Paper ASP TSGWP11-01 <strong>for</strong> review by the TSG during the meeting in June 2011 in Paris<br />

1<br />

2<br />

MSB<br />

3<br />

4<br />

AF=2, TYPE CODE = 1<br />

5 LSB<br />

6 STATUS<br />

7 CHARACTER FIELD (see 1)<br />

8 C1<br />

9 A1<br />

10 C2<br />

11 A2<br />

12 C4<br />

13 A4<br />

14 X MODE 1 CODE<br />

15 B1<br />

16 D1<br />

17 B2<br />

18 D2<br />

19 B4<br />

20 D4<br />

21 STATUS<br />

22 C1<br />

23 A1<br />

24 C2<br />

25 A2<br />

26 C4<br />

27 A4<br />

28 X MODE 2 CODE<br />

29 B1<br />

30 D1<br />

31 B2<br />

32 D2<br />

33 B4<br />

34 D4<br />

35 STATUS<br />

36 C1<br />

37 A1<br />

38 C2<br />

39 A2<br />

40 C4<br />

41 A4<br />

42 X MODE A CODE<br />

43 B1<br />

44 D1<br />

45 B2<br />

46 D2<br />

47 B4<br />

48<br />

49<br />

50<br />

51<br />

D4<br />

52<br />

53<br />

54<br />

55<br />

56<br />

RESERVED<br />

Table A-2-242. BDS code F,2 — Military applications<br />

PURPOSE: This register is used <strong>for</strong> military applications involving DF=19.<br />

Its purpose is to provide data in support of military applications.<br />

‘TYPE CODE’ shall be encoded as follows:<br />

0 = UnassignedReserved<br />

1 = <strong>Mode</strong> code in<strong>for</strong>mation<br />

2-31 = UnassignedReserved<br />

1) The character field shall be used to indicate whether 2 characters or 4<br />

characters are used in the <strong>Mode</strong> 1 code. The logic shall be as follows:<br />

0 = 2 octal codes<br />

(A1 — A4 <strong>and</strong> B1 — B4)<br />

1 = 4 octal codes<br />

(A1 — A4, B1 — B4, C1 — C4 <strong>and</strong> D1 — D4)<br />

2) The status fields shall be used to indicate whether the data are available or<br />

unavailable. The logic shall be as follows:<br />

0 = Unavailable<br />

1 = Available<br />

DF = 19 Application Field (AF) shall be encoded as follows:<br />

0 = Reserved <strong>for</strong> civil extended squitter <strong>for</strong>mats<br />

1 = Reserved <strong>for</strong> <strong>for</strong>mation flight<br />

2 = Reserved <strong>for</strong> military applications<br />

3–7 = Reserved<br />

Draft<br />