A-70 <strong>Technical</strong> <strong>Provisions</strong> <strong>for</strong> <strong>Mode</strong> S <strong>Services</strong> <strong>and</strong> <strong>Extended</strong> <strong>Squitter</strong><br />

MB FIELD<br />

DRAFT - Working Paper ASP TSGWP11-01 <strong>for</strong> review by the TSG during the meeting in June 2011 in Paris<br />

1 MSB<br />

2 FOM/SOURCE<br />

3<br />

4 LSB<br />

5 STATUS (wind speed <strong>and</strong> direction)<br />

6 MSB = 256 knots<br />

7<br />

8<br />

9 WIND SPEED<br />

10<br />

11 Range = [0, 511] knots<br />

12<br />

13<br />

14 LSB = 1 knot<br />

15 MSB = 180 degrees<br />

16<br />

17<br />

18 WIND DIRECTION (True)<br />

19<br />

20 Range = [0, 360] degrees<br />

21<br />

22<br />

23 LSB =180/256 degrees<br />

24 SIGN<br />

25 MSB = 64°C<br />

26<br />

27<br />

28<br />

29 STATIC AIR TEMPERATURE<br />

30<br />

31 Range = [–128, +128] °C<br />

32<br />

33<br />

34 LSB = 0.25°C<br />

35 STATUS<br />

36 MSB = 1 024 hPa<br />

37<br />

38<br />

39<br />

40<br />

41<br />

AVERAGE STATIC PRESSURE<br />

42<br />

43<br />

44<br />

45<br />

Range = [0, 2 048] hPa<br />

46 LSB = 1 hPa<br />

47 STATUS<br />

48 MSB TURBULENCE (see 1)<br />

49 LSB<br />

50 STATUS<br />

51<br />

52<br />

MSB = 100 %<br />

53 HUMIDITY<br />

54<br />

55<br />

Range = [0, 100] %<br />

56 LSB = 100/64 %<br />

Table A-2-68. BDS code 4,4 — Meteorological routine air report<br />

PURPOSE: To allow meteorological data to be collected by<br />

ground systems.<br />

FOM/SOURCE coding:<br />

The decimal value of the binary coded (figure of merit)<br />

FOM/SOURCE parameter shall be interpreted as follows:<br />

0 = Invalid<br />

1 = INS<br />

2 = GNSS<br />

3 = DME/DME<br />

4 = VOR/DME<br />

5 to 15 = Reserved<br />

1) The interpretation of the two bits assigned to TURBULENCE shall be as<br />

shown in the table <strong>for</strong> register 4516.<br />

Note 1.— The average static pressure is not a requirement of Annex 3.<br />

Note 2.— Two’s complement coding is used <strong>for</strong> all signed fields as<br />

specified in §A.2.2.2.<br />

Note 3.— The requirement <strong>for</strong> the range of wind speeds in Annex 3 is<br />

from 0 to 250 knots.<br />

Note 4.— The requirement <strong>for</strong> the range of static air temperature in<br />

Annex 3 is from –80° C to +60° C.<br />