CONELOG ® IMPLANT SYSTEM<br />
PROSTHETIC RESTORATIONS<br />
CONELOG ®<br />
BALL ABUTMENT<br />
INTRODUCTION<br />
In implantological hybrid prosthetics, ball abutment restorations represent<br />
movable anchorings that allow rotational movements of the prosthesis in<br />
one or more directions respectively vertical translation movements. Ball<br />
abutments should generally be perpendicular to the occlusal plane to make<br />
axial loading of the implant possible.<br />
TASKS OF A BALL ANCHORING RESTORATION:<br />
• Protecting the prosthesis against shearing and lifting forces<br />
• Shear distribution<br />
• Possible axial transfer of mastication forces between the prosthesis<br />
and implant<br />
• Resilience compensation through degrees of freedom<br />
PRODUCT DESCRIPTION<br />
The driver for CONELOG ® ball abutments, manual/wrench, is used to<br />
screw the CONELOG ® ball abutments into their final positions in the<br />
CONELOG ® implants. The torque for CONELOG ® ball abutment Ø 3.3 mm<br />
is 20 Ncm and 30 Ncm for Ø 3.8/4.3/5.0 mm.<br />
122<br />
INDICATIONS:<br />
• Resilient anchoring of implant-supported full dentures for the<br />
edentulous maxilla and/or mandible in combination with 2 CONELOG ®<br />
implants to secure a tangential rotation axis.<br />
• Anchoring of implant-supported full dentures for the edentulous<br />
maxilla and/or mandible in combination with 4 CONELOG ® implants.<br />
CONTRAINDICATIONS:<br />
• Uneven number of implants per arch<br />
• Improperly placed implants that prevent a tangential rotation axis<br />
• Combination with other retention devices<br />
• Use with disparallel-placed implants with an angulation of more than<br />
10° to the implant axis<br />
CONELOG ® ball abutments are color-coded and available for CONELOG ®<br />
implants in the 3.3/3.8/4.3/5.0 mm diameters in various gingival heights.<br />
CONELOG ® ball abutment sets are also available consisting of a CONELOG ®<br />
ball abutment, matrix CM Dalbo ® Ball abutment plateau<br />
Ball diameter 2.25 mm<br />
Plus, red duplication aid/spacer, stabilizing<br />
ring and ball abutment analog. The ball diameter is 2.25 mm. 1.5 mm<br />
Driver for CONELOG ® Ball abutments<br />
Gingival heights of CONELOG ® Ball abutments<br />
Driver for CONELOG ® ART. NO. ARTICLE MATERIAL<br />
J5300.0011 Ball abutments,<br />
for Ø 3.3/3.8/4.3/5.0 mm<br />
Stainless steel<br />
3 mm<br />
4.5 mm<br />
After insertion, the ball abutment plateau should be at least 1.0 mm supragingival.