CONELOG ® IMPLANT SYSTEM<br />

PROSTHETIC RESTORATIONS<br />

CONELOG ®<br />

BALL ABUTMENT<br />

INTRODUCTION<br />

In implantological hybrid prosthetics, ball abutment restorations represent<br />

movable anchorings that allow rotational movements of the prosthesis in<br />

one or more directions respectively vertical translation movements. Ball<br />

abutments should generally be perpendicular to the occlusal plane to make<br />

axial loading of the implant possible.<br />

TASKS OF A BALL ANCHORING RESTORATION:<br />

• Protecting the prosthesis against shearing and lifting forces<br />

• Shear distribution<br />

• Possible axial transfer of mastication forces between the prosthesis<br />

and implant<br />

• Resilience compensation through degrees of freedom<br />

PRODUCT DESCRIPTION<br />

The driver for CONELOG ® ball abutments, manual/wrench, is used to<br />

screw the CONELOG ® ball abutments into their final positions in the<br />

CONELOG ® implants. The torque for CONELOG ® ball abutment Ø 3.3 mm<br />

is 20 Ncm and 30 Ncm for Ø 3.8/4.3/5.0 mm.<br />

122<br />

INDICATIONS:<br />

• Resilient anchoring of implant-supported full dentures for the<br />

edentulous maxilla and/or mandible in combination with 2 CONELOG ®<br />

implants to secure a tangential rotation axis.<br />

• Anchoring of implant-supported full dentures for the edentulous<br />

maxilla and/or mandible in combination with 4 CONELOG ® implants.<br />

CONTRAINDICATIONS:<br />

• Uneven number of implants per arch<br />

• Improperly placed implants that prevent a tangential rotation axis<br />

• Combination with other retention devices<br />

• Use with disparallel-placed implants with an angulation of more than<br />

10° to the implant axis<br />

CONELOG ® ball abutments are color-coded and available for CONELOG ®<br />

implants in the 3.3/3.8/4.3/5.0 mm diameters in various gingival heights.<br />

CONELOG ® ball abutment sets are also available consisting of a CONELOG ®<br />

ball abutment, matrix CM Dalbo ® Ball abutment plateau<br />

Ball diameter 2.25 mm<br />

Plus, red duplication aid/spacer, stabilizing<br />

ring and ball abutment analog. The ball diameter is 2.25 mm. 1.5 mm<br />

Driver for CONELOG ® Ball abutments<br />

Gingival heights of CONELOG ® Ball abutments<br />

Driver for CONELOG ® ART. NO. ARTICLE MATERIAL<br />

J5300.0011 Ball abutments,<br />

for Ø 3.3/3.8/4.3/5.0 mm<br />

Stainless steel<br />

3 mm<br />

4.5 mm<br />

After insertion, the ball abutment plateau should be at least 1.0 mm supragingival.