CONELOG ® IMPLANT SYSTEM<br />

PROSTHETIC RESTORATIONS<br />

CONELOG ®<br />

LOCATOR ® ABUTMENT<br />

CONVERTING AN EXISTING FULL<br />

DENTURE INTO A LOCATOR ® -RETAINED<br />

FULL DENTURE<br />

Locator ® components can also be integrated in an existing full denture. After<br />

final insertion of the CONELOG ® Locator ® abutments in the CONELOG ®<br />

implants (see page 138), the Locator ® impression caps are positioned on<br />

the abutments. Note the proper seating.<br />

The existing prosthesis is then hollow ground in the area of the impression<br />

caps.<br />

IMPORTANT NOTE<br />

The impression caps on the CONELOG ® Locator ® abutments must not<br />

come into contact with the prosthesis when checking the fit in the<br />

mouth.<br />

The impression taking in this case is identical to a relining and is taken using<br />

the hollow ground prosthesis directly over the impression caps. To ensure<br />

that the impression caps remain in the impression, we recommend using<br />

suitable impression material such as polyether and silicone compounds<br />

OPTION: With a small denture base, an impression can also be taken with<br />

the titanium housings with black processing replacement males. The reduced<br />

retention in the impression must be taken into account.<br />

142<br />

CAST FABRICATION<br />

The Locator ® analogs are placed in the Locator ® impression caps. Pay attention<br />

to the proper seating of the analogs.<br />

The cast is then fabricated with suitable model material.<br />

CONVERTING THE FULL DENTURE<br />

After fabricating the cast, the white block out spacers included in the<br />

Locator ® male processing package are pulled over the functional areas of<br />

the Locator ® analogs to prevent acrylic from getting into the titanium housings.<br />

White block out spacer<br />

The titanium housings with the black processing replacement males are<br />

placed on each analog over the previously placed block out spacer until the<br />

pressure point is reached.