01<br />

01<br />

<br />

Selected Active Port<br />

Available values are 01 and 02.<br />

REDUNDANCY<br />

User Manual<br />

Operation and Management<br />

The <strong>IRD</strong>-<strong>2900</strong> IP front end supports both physical link and logical source<br />

redundancy. The physical link and logical source are coupled, i.e. switching from<br />

one physical link to the other (in the case of a link redundancy event) forces<br />

switching from the corresponding logical source to the other. In the case of a<br />

logical source redundancy event, the physical links are switched as well.<br />

• Link Redundancy: protects the directly connected switch/router and the<br />

physical cable connection. There are two IP physical links to the <strong>IRD</strong>-<strong>2900</strong>:<br />

MPEGoIP IN1 and .MPEGoIP IN2.<br />

• Source Redundancy: protects the transport stream source<br />

(encoder/streamer). Two logical sources (i.e. sockets), containing identical<br />

streams, must be configured to enable Source redundancy.<br />

REDUNDANCY EVENT<br />

A redundancy event causes the <strong>IRD</strong>-<strong>2900</strong> to switch from the active Physical Link<br />

and Logical Source to the passive ones.<br />

The device identifies a redundancy event when all the following conditions apply:<br />

• Redundancy mode is enabled<br />

• Active physical link failure (through PHY indication) or active logical source<br />

failure detection (no stream is being received for a preconfigured<br />

Redundancy Delay time [see next page)<br />

• Passive physical link is configured, up, and connected<br />

• Passive logical source is configured and connected<br />

The following menu is used for enabling or disabling the operation of the<br />

redundancy feature.<br />

Redundancy<br />

1���� ENABLE<br />

ENABLE<br />

2���� DISABLE<br />

DISABLE<br />

Page 4-52 (Rev. 4.6/ SW v1.80/ December 2007)