4.2.10.3. Embedded Mode<br />

This feature will be supported in the future software releases.<br />

4.2.10.4. Automatic Cam Reset<br />

User Manual<br />

Operation and Management<br />

Automatic Cam Reset mechanism handles scenarios where the CAM ceases to<br />

function correctly, resulting in no decryption of services and therefore video stop<br />

or freezing. Although frozen, the video output remains a valid signal.<br />

The <strong>IRD</strong>-<strong>2900</strong> heuristically detects the CAM error and reset the CAM module.<br />

CAM ERROR DETECTION:<br />

The <strong>IRD</strong>-<strong>2900</strong> detects CAM errors by performing a video lock test that<br />

recognizes faulty video output signals which last longer then the configurable<br />

threshold time.<br />

CAM RESET:<br />

When an error is detected, the <strong>IRD</strong> automatically resets the CAM. Reset time<br />

may take 10 to 20 seconds.<br />

CONFIGURING CAM TIMEOUT:<br />

The CAM Timeout can be configured through CLI.<br />

To configure the CAM Timeout through the CLI:<br />

1. Go to config/video/general/<br />

2. Set decoding timeout by using the following command:<br />

< timeout (seconds), or 0 = disable><br />

The default CAM Timeout is 10 seconds.<br />

To disable the Automatic CAM reset mechanism set the timeout value to 0.<br />

NOTE<br />

Scopus recommends setting the CAM Timeout value to five seconds or higher.<br />