<strong>ATM</strong> <strong>Option</strong><br />
5.3.17 IP RIP TX/RX<br />
This parameter sets the directionality of the RIP version used on the PVC connection.<br />
Configure the PVC for two-way IP RIP routing by setting this parameter to DUPLEX (the<br />
default value). The NetPerformer can generate IP routing tables, and both receive and<br />
transmit RIP frames on this PVC.<br />
You can also enable IP RIP in a single direction. Select the TX ONLY value to allow the<br />
NetPerformer to transmit RIP frames only. The NetPerformer will discard all RIP frames<br />
received at the PVC. Select RX ONLY to allow the NetPerformer to receive RIP frames<br />
only. In this case, the PVC cannot transmit a RIP frame.<br />
5.3.18 IP RIP authentication type<br />
5.3.19 IP RIP password<br />
Console SNMP Text-based Config<br />
IP RIP TX/RX atmpvcIpRipTxRx [atmpvc#] IpRipTxRx<br />
Values: DUPLEX, TX ONLY, RX ONLY<br />
Default: DUPLEX<br />
Console SNMP Text-based Config<br />
IP RIP authentication<br />
type<br />
For IP RIP Version 2 only.<br />
This parameter enables or disables password authentication for the interface. Select<br />
SIMPLE to have the password included in all RIP frames sent from this PVC. Frames<br />
containing authentication that are received at this PVC will be accepted only if the<br />
password is valid. The password is defined using the IP RIP Password parameter,<br />
described below.<br />
Values: NONE, SIMPLE<br />
Default: NONE<br />
atmpvcIpRipAuthType [atmpvc#] IpRipAuthType<br />
Console SNMP Text-based Config<br />
IP RIP password atmpvcIpRipPassword [atmpvc#] IpRipPassword<br />
For IP RIP Version 2 only.<br />
This parameter defines the password to be used on the interface. The password allows the<br />
authentication procedure to generate and/or verify the authentication field in the RIP<br />
header.<br />
NOTE: The value of the IP RIP Password parameter must be the same for each inter-<br />