ATM Option System Reference - Comtech EF Data
ATM Option System Reference - Comtech EF Data
ATM Option System Reference - Comtech EF Data
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
5.5 FRF.8 Mode<br />
5.5.1 Port<br />
5.5.2 DLCI address<br />
SE/PVC Configuration Parameters<br />
NOTE: FRF.8 mode parameters that are common to other PVC modes are described<br />
in the section “<strong>ATM</strong>PVCR Mode” on page 5-4.<br />
Console SNMP Text-based Config<br />
Port atmpvcFrPort [atmpvc#] FrPort<br />
Set to the port or channel number that provides the Frame Relay access link.<br />
NOTE: This list is automatically generated by the NetPerformer, and can include<br />
built-in serial ports, ports on a Dual Serial interface card, and digital data<br />
channels. From this list, you must select a port or channel configured with<br />
the FR-USER protocol.<br />
Values: automatically generated list of ports and channels<br />
Default: 1<br />
Console SNMP Text-based Config<br />
DLCI address atmpvcDlciAddress [atmpvc#] DlciAddress<br />
This parameter determines the <strong>Data</strong> Link Connection Identifier (DLCI) address of the<br />
PVC. To have the unit learn the DLCI address automatically from the Frame Relay switch,<br />
set this parameter to zero (0, the default value). AUTO DLCI is applicable to PVCs in<br />
PVCR mode only. The NetPerformer obtains the correct address for the PVCR PVC from<br />
the network through the Full Status Report. In the factory setup, 8 PVCR PVCs with<br />
AUTO DLCI are allocated on Port 1.<br />
To set this parameter manually, select a non-zero value. When the PVC is set in PVCR,<br />
RFC1490 or TRANSP mode this address is provided by the carrier, and represents the<br />
virtual circuit identification for accessing the remote unit. When the PVC is set in<br />
MULTIPLEX mode, the DLCI address must be the same as that of the Frame Relay enduser<br />
device attached to the NetPerformer port that this PVC uses.<br />
NOTE: This parameter is not required for a PVC in <strong>ATM</strong>-MULTIPLEX mode.<br />
Memotec Inc. 5-31