ATM Option System Reference - Comtech EF Data
ATM Option System Reference - Comtech EF Data
ATM Option System Reference - Comtech EF Data
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SE/PVC Configuration Parameters<br />
of this parameter determines how sensitive the local voice channel will be to the signal<br />
from the attached device. The lower the value, the more sensitive the voice channel is to<br />
the input, and the louder the voice output at the remote end will sound.<br />
5.4.4 Local outbound voice level (db)<br />
5.4.5 Echo canceler<br />
Values: -22 - +7 dB<br />
Default: 0 dB<br />
Specifies the local voice level going out of the port, measured in 1 dB increments. The<br />
higher the value, the louder the volume will be.<br />
Enables or disables echo cancellation on the channel. Echo canceling automatically<br />
reduces echo to tolerable levels. It adapts automatically to changes in the echo that may<br />
occur in successive connections along the virtual path. It also minimizes background noise<br />
and prevents the negative effects of double talk<br />
5.4.6 Double talk threshold (db)<br />
Console SNMP Text-based Config<br />
Local outbound voice<br />
level (db)<br />
Values: -22 - +7 dB<br />
Default: -3 dB<br />
atmpvcVoiceLocalOutbound<br />
[atmpvc#] VoiceLocalOutbound<br />
Console SNMP Text-based Config<br />
Echo canceler atmpvcVoiceEchoCanceler<br />
Values: DISABLE, ENABLE<br />
Default: ENABLE<br />
[atmpvc#] VoiceEcho-<br />
Canceler<br />
Console SNMP Text-based Config<br />
Double talk threshold (db) atmpvcVoiceDTalk-<br />
Threshold<br />
[atmpvc#] VoiceDTalk-<br />
Threshold<br />
Configures the echo cancellation threshold. It can be set to a value in the range -12 to +12<br />
dB, or disabled. If you experience an echo during voice calls, adjust the value up or down<br />
until the echo disappears.<br />
Values: -12 - +12 dB, DISABLED<br />
Default: +6 Db<br />
Memotec Inc. 5-23