ATM Option System Reference - Comtech EF Data
ATM Option System Reference - Comtech EF Data
ATM Option System Reference - Comtech EF Data
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SE/PVC/<br />
RFC1483<br />
example<br />
Configuration<br />
PVC<strong>ATM</strong>2>SE<br />
SETUP<br />
Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />
PHONE/<br />
PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/SVC/USER/VLAN,<br />
def:BRIDGE) ? PVC<br />
PVC number (1-300,def:1) ? 5<br />
PVC 5> Mode (def:OFF) ? RFC1483<br />
PVC 5> VPI address (0-255,def:0) ? 1<br />
PVC 5> VCI address (0-65535,def:10) ? 104<br />
PVC 5> Peak cell rate (PCR) (0-3622,def:1000) ?<br />
PVC 5> Payload information rate is 384000 bps<br />
PVC 5> Total information rate is 424000 bps<br />
PVC 5> Remote unit name (def:) ? BOSTON-RFC1483<br />
PVC 5> BRG connection (def:NO) ?<br />
PVC 5> IP connection (def:YES) ?<br />
PVC 5> IP address (def:000.000.000.000) ?<br />
PVC 5> Subnet mask (number of bits) (0-32,def:8) ?<br />
{255.000.000.000}<br />
PVC 5> Frame size (128-8192,def:1500) ?<br />
PVC 5> IP RIP (def:V1) ?<br />
PVC 5> IP RIP TX/RX (def:DUPLEX) ?<br />
PVC 5> OSPF (def:DISABLE) ?<br />
PVC 5> IP multicast active (def:NO) ?<br />
PVC 5> NAT enable (def:NO) ?<br />
PVC 5> IPX connection (def:YES) ?<br />
PVC 5> IPX RIP (def:DISABLE) ?<br />
PVC 5> IPX SAP (def:DISABLE) ?<br />
PVC 5> IPX network number (def:00000000) ?<br />
PVC 5> Filter (def:ALL) ?<br />
• VPI address, VCI address, Peak cell rate, Payload information rate, Total information<br />
rate, Remote unit name, IP address, Subnet mask, IP RIP, IP RIP TX/RX,<br />
OSPF, IP multicast active, NAT enable, IPX connection, IPX RIP, IPX SAP, IPX<br />
network number and Filter are detailed in “<strong>ATM</strong>PVCR Mode” on page 5-4.<br />
Caution: The Remote Unit Name parameter (SNMP pvcRemoteUnit) is optional<br />
for RFC1483 PVCs, and serves only for information purposes. For example, when<br />
you define a Remote Unit Name, the destination of the PVC will be provided in<br />
PVC UP/DOWN alarms (displayed with the Display Alarms (DA) command). You<br />
must ensure that the Remote Unit Name you select does not interfere with an<br />
existing Remote Unit Name in a mixed network of PVCR and RFC1483 links,<br />
as a name conflict will prevent proper connection. The Remote Unit Name<br />
parameter is also optional for <strong>ATM</strong>PPP and RFC1490 PVCs, and the same<br />
precaution must be taken with them.<br />
• The BRG connection, IP connection and Frame size parameters are particular<br />
to a PVC in RFC1483 mode. For details, turn to “RFC1483 Mode” on page 5-<br />
37.<br />
Memotec Inc. 2-23