<strong>ATM</strong> <strong>Option</strong><br />
DE/SLOT<br />
example<br />
8266>DE<br />
DISPLAY ERRORS<br />
Item (BOOTP/CHANNEL/DICT/GROUP/NAT/PORT/PVC/Q922/REDUNDANCY/SLOT/<br />
SVC/<br />
TIMEP,def:BOOTP) ? SLOT<br />
SLOT> Slot number (1/ALL,def:1) ?<br />
SLOT 1><br />
PORT 100> Number of errored seconds.............1<br />
PORT 100> Number of severely errored seconds....0<br />
PORT 100> Number of severely errored frames.....0<br />
PORT 100> Number of unavailable seconds.........0<br />
PORT 100> Number of controlled slip seconds.....624<br />
PORT 100> Number of path code violations........0<br />
PORT 100> Number of line errored seconds........1<br />
PORT 100> Number of bursty errored seconds......0<br />
PORT 100> Number of degraded minutes............0<br />
PORT 100> Number of line code violations........16<br />
PORT 100> Number of CRC errors..................0<br />
PORT 100> Number of frame length errors.........0<br />
PORT 100> Number of abort sequences.............0<br />
PORT 100> Number of non-aligned octets..........0<br />
PORT 100> Number of HDLC framing errors.........0<br />
PORT 100> Number of returned rx buffers.........0<br />
PORT 100> Number of channel restarts............0<br />
PORT 101> No. of frames discarded (overrun).....0<br />
PORT 101> No. of frames discarded (bad).........0<br />
PORT 101> No. of frames discarded (CRC error)...1539<br />
PORT 101> No. of raw cells discarded............1485<br />
PORT 101> No. of cell sync lost.................76496<br />
PORT 101> Invalid VPI.VCI cells received........3<br />
PORT 101> Unsupported OAM cells received........0<br />
Bad flags: U:Bad LENGTH Q:Overflow F:Flush S:Overrun B:Bad CRC<br />
A:Abort<br />