5.4.12 TONE ON (ms)<br />
5.4.13 TONE OFF (ms)<br />
SE/PVC Configuration Parameters<br />
NOTE: The human voice can produce frequencies which may be interpreted as tones<br />
and then regenerated at the remote site if Tone Regeneration is always ON (set<br />
to 1). To avoid tone regeneration during a conversation, it is recommended<br />
that this parameter be enabled for a limited amount of time (set to 2 to 255).<br />
Values: 0 - 255 sec<br />
Default: 30 sec<br />
Specifies the duration, in milliseconds, of the multi-frequency tone the NetPerformer uses<br />
to generate a single digit.<br />
Specifies the duration, in milliseconds, of the silence the NetPerformer uses between<br />
multi-frequency tones when generating a dial digit string.<br />
The actual duration of the multi-frequency tone depends to a great extent on the user’s<br />
actions, especially for telephones that sound a tone for as long as a number push-button is<br />
pressed. People typically execute a tone duration of 100 - 750 ms, with silence periods of<br />
300 - 1500 ms. Much shorter periods result from automated dialing: typically 60 - 120 ms<br />
for tones, with 50 - 150 ms of silence between tones.<br />
5.4.14 Pulse make/break ratio<br />
Console SNMP Text-based Config<br />
TONE ON (ms) atmpvcVoiceToneOn-ms [atmpvc#] VoiceToneOnms<br />
Values: 30 - 1000 ms (in increments of 10)<br />
Default: 30 ms<br />
Console SNMP Text-based Config<br />
TONE OFF (ms) atmpvcVoiceToneOff-ms [atmpvc#] VoiceToneOffms<br />
Values: 30 - 1000 ms (in increments of 10)<br />
Default: 30 ms<br />
Console SNMP Text-based Config<br />
Pulse make/break ratio atmpvcVoicePulseMake-<br />
Break-ms<br />
[atmpvc#] VoicePulse-<br />
MakeBreak-ms<br />
Memotec Inc. 5-27