2.5 Configuring the Digital Link<br />

Configuration<br />

Set up the digital link for an <strong>ATM</strong> interface with the LINK option of the the SETUP/SLOT<br />

command.<br />

To configure the digital link:<br />

1. At the NetPerformer command line prompt, enter the menu sequence: SE � SLOT<br />

2. Select the Slot number of a slot that contains a T1 or E1 interface card<br />

3. Enter LINK<br />

Unit ID><br />

(main prompt)<br />

Caution: If you change the configuration of a T1 or E1 interface card<br />

while voice calls are active, the calls will be disrupted.<br />

4. Set the Status parameter to ENABLE<br />

5. Set Clock Recovery to ENABLE<br />

6. Set Digital port clock source to the appropriate value for your application:<br />

• INTERNAL to use the internal reference clock<br />

• 1 to 4 to use the clock received from the network via the digital interface card<br />

installed in that slot number<br />

7. Set the Signaling Mode to NONE<br />

Setup (SE)<br />

Figure 2-3: SETUP/SLOT/LINK Path in the CLI Tree<br />

8. Change the other parameters from their default values, if desired.<br />

Slot (SL)<br />

Memotec Inc. 2-13<br />

Link<br />

NONE