2.5 Configuring the Digital Link<br />
Configuration<br />
Set up the digital link for an <strong>ATM</strong> interface with the LINK option of the the SETUP/SLOT<br />
command.<br />
To configure the digital link:<br />
1. At the NetPerformer command line prompt, enter the menu sequence: SE � SLOT<br />
2. Select the Slot number of a slot that contains a T1 or E1 interface card<br />
3. Enter LINK<br />
Unit ID><br />
(main prompt)<br />
Caution: If you change the configuration of a T1 or E1 interface card<br />
while voice calls are active, the calls will be disrupted.<br />
4. Set the Status parameter to ENABLE<br />
5. Set Clock Recovery to ENABLE<br />
6. Set Digital port clock source to the appropriate value for your application:<br />
• INTERNAL to use the internal reference clock<br />
• 1 to 4 to use the clock received from the network via the digital interface card<br />
installed in that slot number<br />
7. Set the Signaling Mode to NONE<br />
Setup (SE)<br />
Figure 2-3: SETUP/SLOT/LINK Path in the CLI Tree<br />
8. Change the other parameters from their default values, if desired.<br />