SVC 3> Speed used (bps).........................424 k<br />
SVC 3> SVC Status...............................UP<br />
SVC 3> SVC Local address..........<br />
........................47009181000000003080191D01A0000000000200<br />
SVC 3> SVC Destination address....<br />
........................47009181000000003080191D01B0000000000200<br />
SVC 3> VPI......................................0<br />
SVC 3> VCI......................................162<br />
SVC 3> State & Delay............................DATA 0ms<br />
---- SVC #3 FRF.8 --> FR port #1 ----<br />
SVC 3> Information signals......................USER -A---<br />
SVC 3> Speed used (bps).........................56000<br />
SVC 3> DLCI.....................................111<br />
SVC 3> State & Delay............................DATA 0ms<br />
SVC 4> Mode.....................................RFC1483<br />
SVC 4> Information signals......................-A---<br />
SVC 4> Speed used (bps).........................424 k<br />
SVC 4> SVC Status...............................UP<br />
SVC 4> SVC Local address..........<br />
........................47009181000000003080191D01A0000000000300<br />
SVC 4> SVC Destination address....<br />
........................47009181000000003080191D01B0000000000300<br />
SVC 4> VPI......................................0<br />
SVC 4> VCI......................................172<br />
SVC 4> PVC name.................................<br />
SVC 4> State & Delay............................DATA 0ms<br />
SVC 5> Mode.....................................<strong>ATM</strong>PPP<br />
SVC 5> Information signals......................-A---<br />
SVC 5> Speed used (bps).........................424 k<br />
SVC 5> SVC Status...............................UP<br />
SVC 5> SVC Local address..........<br />
........................47009181000000003080191D01A0000000000400<br />
SVC 5> SVC Destination address....<br />
........................47009181000000003080191D01B0000000000400<br />
SVC 5> VPI......................................0<br />
SVC 5> VCI......................................173<br />
SVC 5> PVC name.................................<br />
SVC 5> State & Delay............................DATA 0ms<br />
Info signals: NETwork/USER (N)ew (A)ctive (C)ir (F)ecn (B)ecn (-<br />
)off<br />
NOTE: Most of these statistics are also displayed for an <strong>ATM</strong> PVC connection. The<br />
SVC-specific statistics include the following:<br />
3-6 Memotec Inc.