20.02.2013 Views

ATM Option System Reference - Comtech EF Data

ATM Option System Reference - Comtech EF Data

ATM Option System Reference - Comtech EF Data

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ATM</strong> <strong>Option</strong><br />

• A 15-digit E.164 address: Indicates that the SVC is connected to a public <strong>ATM</strong><br />

network.<br />

3.2.3 Displaying the SVC Errors (DE/SVC)<br />

To display the error counters for an <strong>ATM</strong> SVC:<br />

• At the NetPerformer command line prompt, enter the menu sequence: DE � SVC<br />

DE/SVC/<strong>ATM</strong><br />

example SVC<strong>ATM</strong>1>DE<br />

DISPLAY ERRORS<br />

Item (BOOTP/CHANNEL/DICT/GROUP/NAT/PORT/PU/PVC/Q922/SLOT/SVC/<br />

TIMEP,<br />

def:BOOTP) ? SVC<br />

SVC 1> Number of frames discarded (crc error)...0<br />

SVC 1> Number of frames discarded (overrun).....0<br />

SVC 1> Number of invalid frames discarded.......0<br />

SVC 1> Other frames discarded...................0<br />

---- SVC #2 FRF.8 --> <strong>ATM</strong> Side ----<br />

SVC 2> Number of frames discarded (crc error)..0<br />

SVC 2> Number of frames discarded (overrun)....0<br />

SVC 2> Number of invalid frames discarded......0<br />

SVC 2> Other frames discarded..................0<br />

---- SVC #2 FRF.8 --> FR port #1 ----<br />

SVC 2> Number of errors........................0<br />

SVC 2> Number of restarts......................0<br />

SVC 2> Number of invalid frames discarded......0<br />

SVC 2> Number of frames discarded (overrun)....0<br />

SVC 2> Number of invalid octets discarded......0<br />

SVC 2> Number of octets discarded (overrun)....0<br />

NOTE: These statistics are also displayed for an <strong>ATM</strong> PVC connection. In the example<br />

above, statistics for SVC 2 are unique to an SVC in FRF.8 mode, and<br />

show both the <strong>ATM</strong> side and the Frame Relay port side of the connection.<br />

3.2.4 Continuous Display of SVC States (DSVC)<br />

The DSVC command provides a continuously updated display of <strong>ATM</strong> SVC status in real<br />

time.<br />

To display the status of <strong>ATM</strong> SVCs in real time:<br />

1. Enter DSVC<br />

2. Enter <strong>ATM</strong> as the SVC TYPE.<br />

3-8 Memotec Inc.