SE/PVC Configuration Parameters<br />

• The CIR if the BIR is not effective or if congestion occurred while running at the<br />

BIR.<br />

A full explanation of how to fine tune the CIR and BIR appears in the section<br />

Information Rate Parameters in the Extended Parameters fascicle of this document<br />

series.<br />

5.5.4 Burst Information rate<br />

NOTE: This parameter is not used for PVCs in <strong>ATM</strong>PVCR or <strong>ATM</strong>-MULTIPLEX<br />

mode. Consult “Service Categories” on page 1-10 for a description of all factors<br />

that affect cell rate pacing when these modes are selected.<br />

Values: 4000 - 6144000<br />

Default: 56000<br />

Console SNMP Text-based Config<br />

Burst Information rate atmpvcBurstInfoRate [atmpvc#] BurstInfoRate<br />

PVC Burst Information Rate (BIR) in bits per second. The BIR represents the data<br />

throughput when the PVC is in burst mode. For example, if you configure the BIR at<br />

64000 bps and the CIR at 56000 bps, the NetPerformer will transmit at 64000 bps unless<br />

congestion occurs, when the rate will be reduced to 56000 bps.<br />

NOTE: Two Extended Parameters also control the information rate of Frame Relay<br />

connections. Together these parameters can be used to adjust the committed<br />

and burst rate sampling timers on networks that integrate bursty high-speed<br />

traffic with constant low-speed traffic. They are described in the section<br />

Information Rate Parameters in the Extended Parameters fascicle of<br />

this document series.<br />

NOTE: This parameter is not used for PVCs in <strong>ATM</strong>PVCR or <strong>ATM</strong>-MULTIPLEX<br />

mode. Consult “Service Categories” on page 1-10 for a description of all factors<br />

that affect cell rate pacing when these modes are selected.<br />

Values: 4000 - 6144000<br />

Default: 56000<br />