USER’S MANUAL AND MAINTENANCE<br />
If the PLC goes into stand-by, press the reset button or key F2 to resume normal operation.<br />
The machine will be able to start work again after a few minutes.<br />
ALARMS<br />
While the machine is running, the operator will be helped by a series of ALARMS which will<br />
appear on the display. The alarm number and glue tray temperature temperature will flash on the the display<br />
alternately and and the operator will be informed of machine status, malfunctions malfunctions and machine<br />
alarms.<br />
When an an alarm is triggered during machine operation, all machine movements movements enabled enabled at that<br />
moment will be disabled.<br />
Description of alarms<br />
ALARM 01: piece too short;<br />
ALARM 02: minimum spacing between panels (1000 mm S1-S8) (1450 mm S1 eco);<br />
ALARM 03: no air from pneumatic plant (check air pressure is correct, about 6 bar);<br />
ALARM 04: remove pieces from the conveyor belt;<br />
ALARM 05: end-trimming machine 1 not in position (lubricate runners, observe the distance<br />
between the panels and check the air pressure is correct);<br />
ALARM 06: end-trimming machine 2 not in position (lubricate runners, observe the distance<br />
between the panels and check the air pressure is correct);<br />
ALARM 07: temperature sensor fault (check sensor condition and replace if necessary);<br />
ALARM 08: machine is not at its ideal temperature;<br />
ALARM 09: emergencies (check that no emergency buttons have been pressed and that no<br />
doors are open);<br />
ALARM 10: belt speed too slow (check that the panel thickness matches the pressure bar<br />
regulation);<br />
ALARM 11: memory fault (contact after-sales service).<br />
The alarms are illustrated on a label so that OPERATORS can consult them more easily.<br />