Pull cord switch, order no. 19 0707 20x<br />
19 070720J incl. frame Jung AS 500<br />
19 070720B incl. frame Berker S.1<br />
19 070720G incl. frame Gira Standard 55 matt<br />
19 070720GG incl. frame Gira Standard 55 glossy<br />
19 070720M incl. frame Merten System M-SMART<br />
Pull cord switch with 2 m pull cord and call handle for raising<br />
calls by pulling the cord. The reassurance light lights up as soon<br />
as a call is raised. Incl. frame and central plate.<br />
Connection to terminal, display module or call/presence combi‐<br />
nation bus (RAB). The call type depends on the input to which<br />
the pull cord switch is connected.<br />
Weight : approx. 90 g<br />
Standby current consumption: 0.05 mA<br />
Maximum current consumption: 10 mA<br />
Note! Complete installation of the system is described<br />
in the <strong>Technical</strong> <strong>Manual</strong>..<br />
Mounting<br />
Wall or ceiling mounting on 1-gang back box.<br />
1. Strip the connecting cable to a suitable length. Remove the<br />
cable shield and the ground wire up to the cable sheath.<br />
2. If you want to connect the switch to a terminal, order no.<br />
19 0700 x0, or display module, order no. 19 0700 80, or a<br />
RAB, order no. 19 0701 00, connect the connecting cable to<br />
the connector 8 as per Fig. D.<br />
3. If you want to connect the switch to a terminal, order no.<br />
10 0700 x0, or display module, order no. 10 0700 8x, or a<br />
RAB, order no. 10 0701 x0, connect the connecting cable to<br />
the connector 8 as per Fig. E.<br />
4. Screw the pull cord switch insert 5 and the sealing flange 6<br />
onto the back box 7 with the screws 4 of the back box. When<br />
doing this, pay attention to the orientation of the ”top”<br />
marking.<br />
5. Insert central plate 2 into the frame 3.<br />
6. Press the central plate 2 together with frame 3 onto the pull<br />
cord switch insert until it engages audibly on both sides.<br />
7. Shorten the pull cord 1 to the desired length and knot it again<br />
in the call handle. Attention! The call handle must not be more<br />
than 200 mm above the floor.<br />
Dismantling<br />
1. Lever frame 3 together with central plate 2 off the wall using a<br />
screw driver, see Fig. C.<br />
2. Undo the screws 4 of the back box and remove the pull cord<br />
switch insert 5 with the sealing flange 6 from the back box.<br />
3. Unscrew the connecting cable from the connector on the rear<br />
of the pull cord switch insert 5.<br />
00 8814 05, 10/12 (Rev. 2.0) 1<br />
<strong>Technical</strong> <strong>Manual</strong> Page 105<br />
1<br />
Front side:<br />
7 2<br />
1<br />
2<br />
4*<br />
3<br />
top<br />
5 Rear side:<br />
8 9<br />
1 Pull cord with call handle<br />
2 Central plate<br />
3 Frame<br />
4* Screws of the back box<br />
5 Pull cord switch insert<br />
6 Sealing flange<br />
7* Back box<br />
8 Connector<br />
9 Plug bridge<br />
* Not included with product delivery<br />
3<br />
4*<br />
top<br />
5<br />
2 3<br />
6<br />
7*