7.3.3 Switches<br />
ÀÀ<br />
ÀÀÀÀÀ<br />
ÀÀÀ<br />
150 mm<br />
300 mm<br />
1,300 mm<br />
1,000 mm<br />
CONCENTO PLUS - <strong>Technical</strong> <strong>Manual</strong>, 11/12 (Rev. 3.0), 00 8814 14<br />
7. Defining mounting positions<br />
Cancel switch next to the door in the WC<br />
Order no.: 19 0708 50, 19 0709 00<br />
A 1-gang back box is required for each switch. .<br />
Call switch<br />
Order no.: 19 0708 00<br />
A 1-gang back box is required for each switch.<br />
The call switch must be easily reachable, e.g. next to the<br />
washbasin.<br />
300 mm Pull cord switch in the bathroom/WC<br />
(ceiling mounting)<br />
300 mm<br />
2,250 mm<br />
Order no.: 19 0707 20x<br />
1-gang back box required.<br />
The special requirements for ”barrier-free living” (DIN 18025)<br />
must be observed in the case of pull cord switches in wet<br />
rooms. Here too, persons lying on the floor must be able to<br />
reach the pull cords. This means that the call handle must not<br />
be more than 200 mm above the floor.<br />
Pull cord switch in the bathroom/WC<br />
(wall mounting)<br />
Order no.: 19 0707 20x<br />
1-gang back box required.<br />
Pull cord switches in wet rooms must be installed at least 200<br />
mm above the highest possible shower head position.<br />
The special requirements for ”barrier-free living” (DIN 18025)<br />
must be observed in the case of pull cord switches in wet<br />
rooms. Here too, persons lying on the floor must be able to<br />
reach the pull cords. This means that the call handle must not<br />
be more than 200 mm above the floor.<br />
53