<strong>Tunstall</strong> <strong>GmbH</strong>, Orkotten 66, D-48291 Telgte, www.tunstall.de<br />

Call/presence combination bus (RAB), order no. 19 0701 00<br />

The call/presence combination bus (RAB) for nurse call systems<br />

CONCENTO PLUS type is used by staff. It includes a green<br />

presence button and a red call button as well as a buzzer for<br />

signalling forwarded calls. The RAB controls all room functions<br />

according to the German standard DIN VDE 0834.<br />

It is possible to use the RAB in an existing nurse call system<br />

„Concento“ type, if it is connected to a ward bus with a group<br />

electronic only of order no.10 0700 10.<br />

A 4-pole and a 12-pole connector included with delivery.<br />

Dimensions (HxWxD): approx. 71 x 71 x 24 mm<br />

Weight incl. central plate and frame: approx. 75 g<br />

Standby current consumption: approx. 10 mA at 24 V DC<br />

Note! The complete installation of the system is<br />

described in the <strong>Technical</strong> <strong>Manual</strong>.<br />

Caution! Electrostatic sensitive components<br />

The printed circuit board includes electrostatic sensitive<br />

components. Therefore avoid touching.<br />

Mounting<br />

Wall mounting on 1-gang back box.<br />

1. Strip the connection cables to the appropriate length. Remove<br />

the cable shield and ground wire up to the cable sheath.<br />

2. Attach the wires according to fig. D to both connectors.<br />

3. Set the three DIP switches (refer to fig. A) according to Fig.<br />

D.<br />

4. Plug both wired connectors to the connection field 7.<br />

5. Screw the RAB 4 with the back box screws 3 to the back<br />

box 5.<br />

6. Insert the central plate 1 in the frame 2.<br />

7. Press the central plate 1 together with the frame 2 onto the<br />

RAB, until it clicks into place.<br />

Dismantling<br />

1. Lever off the frame 2 together with the central plate 1 from the<br />

wall using a screw driver, see fig. C.<br />

2. Unscrew the back box screws 3 and remove the RAB 4 from<br />

the back box.<br />

3. Unplug both connectors from the rear side of the RAB 4.<br />

00 8814 03, 10/12 (Rev. 4.0) 1<br />

<strong>Technical</strong> <strong>Manual</strong> Page 94<br />

6<br />

4 front view<br />

4 rear view<br />

1* Central plate for 2 buttons,<br />

order no. 19 9201 00<br />

2* Frame, internal dimensions: 55 x 55 mm<br />

3* Back box screws<br />

4 RAB<br />

5* Back box, 1-gang<br />

6 DIP switches<br />

7 Connection field<br />

* Not included with delivery.<br />

Registering the room devices in the RAB<br />

So that the room devices that are connected to the inputs of the This is how you have to proceed<br />

RAB (max. 4 room devices per input) are monitored by the RAB<br />

for faults during nurse call operation, they must first be registered<br />

by the RAB.<br />

Press the green button and keep it pressed.<br />

Within 1 second, also press the red button and<br />

keep it pressed for 10 seconds.<br />

The RAB registers all operational room devices<br />

Pre-condition: Terminating resistors are active<br />

with terminating resistor.<br />

The 120 kOhm terminating resistor must be active on all room<br />

devices connected at an input of the RAB. If several devices are<br />

Three short confirmation tones sound.<br />

connected in series, the terminating resistor must be active on<br />

each of these devices. Refer to the installation instructions for the<br />

device for how to activate the terminating resistor.<br />

As an alternative to the described method, you can<br />

disconnect the RAB from the power supply and<br />

then reconnect it. The RAB then registers all opera‐<br />

tional room devices with a terminating resistor<br />

automatically.<br />

1*<br />

3*<br />

2*<br />

2*<br />

1*<br />

7<br />

4<br />

3*<br />

5*