Display module, order no. 19 0700 80<br />
Connecting the wires to the connectors and setting the DIP switches<br />
RL<br />
Room lamp 7 )<br />
AW<br />
WL<br />
Ward bus (data)<br />
GND<br />
IA<br />
WH(YE)<br />
R3<br />
IB<br />
YE<br />
R4<br />
00 8814 02, 10/12 (Rev. 4.0) 2<br />
<strong>Technical</strong> <strong>Manual</strong> Page 91<br />
+24 V<br />
GND<br />
BU<br />
+24 V<br />
+24V<br />
BN<br />
R1<br />
R2<br />
WR<br />
12 11 10 9 8 7 6 5 4 3 2 1<br />
4<br />
IA<br />
R3 = Call button bed 3 1 ) 3 )<br />
R4 = Door alarm 1 ) 2 ) 3 )<br />
IB<br />
3 2 1<br />
GND<br />
R1 = Call button bed 1 1 ) 3 )<br />
+24 V<br />
Display module is first or last ward<br />
bus user (= bus termination).<br />
WC calls can be cancelled with the<br />
WC cancel button or the presence<br />
button.<br />
R2 = Call button bed 2 1 ) 3 )<br />
WC call button 3 )<br />
WC cancel button 3 )<br />
WA<br />
Legend:<br />
1 ) In CONCENTO PLUS systems the call type and<br />
contact type can be changed, refer to chapter<br />
“Configuration“ on page 3.<br />
2 ) In Concento systems R4 = Room call.<br />
3 ) Maximum 4 monitored devices per input.<br />
4 ) RL colour = YE. For room lamp only = RD.<br />
5 ) WL colour = YE. For room lamp only = WH.<br />
6 ) WA colour = WH. For room lamp only = WH(GN).<br />
7 ) Switching power per output: 100 mA at 24 V DC.<br />
One wire<br />
Oour wires<br />
Output<br />
Input<br />
4-pole connector<br />
Max. wire cross-section: 2.5 mm 2<br />
Power supply (input)<br />
Note! All inputs are pre-programmed as NO contacts.<br />
12-pole connector<br />
ON<br />
OFF<br />
1 2<br />
Display module is neither first nor<br />
last ward bus user.<br />
WC calls can be cancelled only with<br />
the WC cancel button.<br />
3<br />
DIP switches 1, 2, 3<br />
DIP Switch ON OFF<br />
Factory Setting<br />
1<br />
2<br />
3<br />
YE 4 )<br />
YE<br />
YE 5 )<br />
BK or BU<br />
WH<br />
WH<br />
RD<br />
RD<br />
WH<br />
Not all ward bus users are<br />
CONCENTO PLUS type. One or more<br />
ward bus users are Concento type,<br />
order no.:<br />
- Group electronic: 10 0700 10<br />
- Terminals: 10 0700 x0<br />
- Display module: 10 0700 8x<br />
- RAB: 10 0701 x0<br />
WH<br />
WH<br />
WH 6 )<br />
All ward bus users are CONCENTO PLUS<br />
type, order no.:<br />
- Group electronic: 19 0700 10<br />
- Terminals: 19 0700 x0<br />
- Display module: 19 0700 80<br />
- RAB: 19 0701 00<br />
OFF<br />
OFF<br />
OFF<br />